INSTALLATION INSTRUCTIONS: Viewline 85 mm

GB

TU00-0752-5807102

Technische Änderungen vorbehalten  -  Technical details subject to change

TU00-0752-5807102

Tachometer

Reconnect the battery after inspecting the connection. 

If necessary, replace the main circuit switch. Turn on the ignition and 

conduct a functional test. Reprogram other instruments that may 

have lost their saved settings.

Align the instrument and hand-tighten the fastening 

nut. Ensure that the nut is not tightened with a torque 

greater than 400 Ncm. 

*  Make sure the seal lays flat between the panel and 

the front ring.

If you would like to omit the fastening nut, you may use 

the part set A2C59510854 as an alternative.  

This is recommended if the installation location is 

 subject to vibratory loads. 

Screw the stud bolts into the provided drill holes in  

the enclosure. Max. stud bolt torque is 1.5 Nm

Place the bracket on the stud bolt and hand-tighten the 

knurled nut. 

*  Make sure the seal lays flat between the panel and 

the front ring (see Fig. 14).

  Please note that when you disconnect the battery, all volatile 

electronic memories lose their input values and must be repro-

grammed.

Summary of Contents for TU00-0752-5807102

Page 1: ...nical and electrical airbag area Do not drill holes or ports in load bearing or stabilizing stays or tie bars When working underneath the vehicle secure it according to the specifications from the veh...

Page 2: ...ion Required mounting depth 65 mm Drill small ports enlarge and complete them if necessary using taper milling tools saber saw keyhole saw or file Debur edges Follow the safety instructions of the too...

Page 3: ...into the drill hole from the back Adjust the instrument so that the gauge is level and fasten it to the stud bolts on the rear side of the panel using the flush mount fixing bracket A2C59510864 If th...

Page 4: ...ducing the cable cross sectional area leads to higher current density which can cause the cable cross sectional area in question to heat up When installing electrical cable use the provided cable duct...

Page 5: ...nut is not tightened with a torque greater than 400 Ncm Make sure the seal lays flat between the panel and the front ring If you would like to omit the fastening nut you may use the part set A2C59510...

Page 6: ...tting the impulse number 1 Activate T 30 8 pin Pin1 2 Deactivate T 15 8 pin Pin4 3 Press and hold Config key 14 pin Pin 11 Activate T 15 Release Config key Press and hold Config key Set impulse number...

Page 7: ...y you can switch between 24h and 12h AM PM clock format Press and hold Mode key Press Mode key briefly Press and hold Mode key Set alarm threshold is displayed the first digit flashes Press Mode key b...

Page 8: ...lay indicator selection 1 Activate T 30 8 pin Pin1 2 Activate T 15 8 pin Pin4 Press Mode key briefly Press Mode key briefly Press Mode key briefly 2 Resetting the day counter 1 Activate T 30 8 pin Pin...

Page 9: ...s to 0 Press and hold Mode key The next lower digit flashes Press Mode key briefly The flashing digit increases by 1 If the flashing digit is 9 the display returns to 0 Continue until the correct time...

Page 10: ...gle contacts 0 14 0 22 mm Tyco No 1355718 1 Single contacts 0 5 0 75 mm Tyco No 963729 1 Strip 0 14 0 22 mm Tyco No 1355717 1 Strip 0 25 0 5 mm Tyco No 928999 1 Strip 0 5 0 75 mm Tyco No 963715 1 Brac...

Page 11: ...r signal Green 6 Lighting Positive Blue Red 7 Warning LED ground Yellow Black 8 Warning LED plus Yellow Red Please read instructions included as some of these pins will not be required Programming Por...

Reviews: