39
INSTALLATION / DATA
Circuit diagram legend:
S1
On/Off switch for navigation instruments
S2
On/Off switch for instrument lighting
F1
Fuse for navigation instruments (5 A)
F2
Fuse for instrument lighting (5 A)
Recommended cable section: 1.5 mm
2
Cable lengths:
Log sending unit - Indicating instrument
20 m max.
Indicating instrument - Repeater
10 m max.
Repeater 1 - Repeater 2
10 m max.
Technical data:
Measuring principle:
Pulse count by Hall sensor
Supply voltage:
10.8 V to 32 V DC
Current consumption:
about 100 mA at 12 V DC (without illumi-
nation), about 260 mA with illumination
Operating temperature:
-10 °C to +60 °C
Type of protection:
DIN 40050 - IP 65 at front
EMC protection:
CE: EN 50081-1, EN 50082-1
Dimensions:
Indicating instrument:
Front ring diameter
105 mm
Installation diameter
86 mm
Installation depth
56 mm (union nut)
Installation depth
90 mm (bracket)
Hull sleeve:
Installation diameter:
39 mm
Maximum hull thickness:
30 mm
Technical modifications reserved
Summary of Contents for Ocean Line Sumlog
Page 3: ...22 ...