85
Article No.
X10-224-009-021
80
1045 ± 2
0.5 ± 0.7
92.7 ± 2.7
I
A2
X10-224-009-029
80
741 ± 2
0.5 ± 0.7
65.0 ± 2.1
I
A2
X10-224-009-037
80
536 ± 2
0.8 ± 0.7
67.2 ± 2.1
I
-
X10-224-009-040
80
1086 ± 2
0.4 ± 0.7
64.1 ± 2.1
I
A2
X10-224-009-045
80
681
0.8 ± 0.7
86.0 ± 2.5
I
-
X10-224-009-048
80
641 ± 2
0.8 ± 0.7
81.0 ± 2.5
n/a
-
X10-224-009-057
80
946 ± 2
0.7 ± 0.7
83.9 ± 2.5
I
A1
X10-224-009-072
80
1387 ± 2
0.5 ± 0.7
82.4 ± 2.5
I
A2
X10-224-014-002
80
686 ± 2
0.8 ± 0.7
86.7 ± 2.5
I
-
X10-224-014-003
80
881 ± 2
0.7 ± 0.7
78 ± 2.4
II
-
X10-224-014-011
80
916 ± 2
0.7 ± 0.7
81.2 ± 2.5
I
A2
X10-224-014-014
80
671 ± 2
0.7 ± 0.7
59.2 ± 1.9
I
A2
X10-224-014-015
80
996 ± 2
0,5 ± 0.7
59.2 ± 1.9
I
A2
X10-224-014-021
80
426 ± 2
1.5 ± 0.7
78.4 ± 2.3
II
A2
X10-224-014-022
80
616 ± 2
1.0 ± 0.7
78.3 ± 2.3
II
A2
X10-224-014-023
80
946 ± 2
0.7 ± 0.7
83.9 ± 2.5
II
A1
X10-224-014-030
80
380 ± 2
2.2 ± 0.7
88.5 ± 2.5
III
A2
X10-224-014-031
80
326 ± 2
1.5 ± 0.7
59.4 ± 1.9
III
A2
X10-224-014-032
80
281 ± 2
1.5 ± 0.7
50.8 ± 1.9
III
A2
X10-224-014-033
80
451 ± 2
1.5 ± 0.7
83.1 ± 2.5
III
A2
X10-224-014-036
80
500 ± 2
1.0 ± 0.7
63.3 ± 2.1
III
A2
X10-224-014-040
80
440 ± 2
1.5 ± 0.7
81.1 ± 2.5
III
A2
X10-224-014-044
80
1250 ± 2
0.5 ± 0.7
74.2 ± 2.3
II
A2
X10-224-021-001
80
536 ± 2
1.0 ± 0.7
67.9 ± 2.1
IV
A1
X10-224-021-002
80
596 ± 2
1.0 ± 0.7
75.5 ± 2.3
IV
A1
X10-224-021-004
80
803 ± 2
0.7 ± 0.7
71.1 ± 2.3
IV
A1
X10-224-021-005
80
1045 ± 2
0.7 ± 0.7
92.9 ± 2.7
IV
A1
X10-224-021-006
80
846 ± 2
0.7 ± 0.7
75.0 ± 2.3
IV
A1
Tubular-Type Senders – Without Warning Contact, Common Ground or Insulated Return* (
ø
80 mm)
Summary of Contents for 360-081-029-004C
Page 1: ...Sensors for Instrumentation V 3 0 www vdo com Sensors for Instrumentation V 3 0...
Page 4: ...4...
Page 10: ...Notes 10...
Page 17: ...17 Pressure Senders With Warning Contact Common Ground...
Page 23: ...23 Tightening Torques for Pressure Senders...
Page 24: ...Notes 24...
Page 28: ...Notes 28...
Page 33: ...33 Temperature Senders Without Warning Contact Common Ground or Insulated Return...
Page 45: ...45 Tightening Torques for Temperature Senders...
Page 46: ...Notes 46...
Page 51: ...51 Temperature Switches Typ A 1 2 3 W Common Ground...
Page 54: ...Notes 54...
Page 66: ...Notes 66...
Page 77: ...77 Lever Type Senders Without Warning Contact Common Ground or Insulated Return special...
Page 78: ...Notes 78...
Page 87: ...87 Tubular Type Senders Accessory Parts...
Page 93: ...93 Tubular Type Senders Without Warning Contact Common Ground or Insulated Return special...
Page 94: ...Notes 94...