background image

ON

DIP

ASSEMBLY INSTRUCTIONS

Technical details subject to change

TU00-0761-5507150

10/18

Warning point adjuster 2910002025200

TU00-0761-5507150

1–3

3

EN

6

For normal operation set switch 3 to ON  

and switch 4 to OFF.

Selecting the warning range:

For the warning with increasing sensor resistance,  

set switch 1 to ON and switch 2 to OFF.

Turn the potentiometer until the pointer is at the posi-

tion where the warning lamp is to be triggered. (During 

the adjusting procedure itself, the warning lamp is not 

triggered depending on the pointer position.)

Selecting the warning range:

For the warning with falling sensor resistance,  

set switch 1 to OFF and switch 2 to ON.

Turn the potentiometer until the pointer is at the posi-

tion where the warning lamp is to be triggered. (During 

the adjusting procedure itself, the warning lamp is not 

triggered depending on the pointer position.)

Examples:

Level gauge with dip tube level sensor, warning if fill 

level is too low (fuel).

Temperature indicator, warning if temperature is too 

low (oil/water).

Pressure indicator, warning if pressure is too high (oil).

Examples:

Pressure indicator, warning if pressure is too low (oil).

Level gauge with lever level sensor, 

warning if fill level is too low (fuel).

Example:

Temperature indicator, warning if temperature is too 

high (oil, water).

8

7

Insert the main power switch again if necessary.  

Switch the ignition on and carry out a functional test.

Re-programme other devices which may have lost your  

saved settings.