ALFA(NET) 51 PI 24Vdc -50/+50°C 

Doc.no.: 150301   version 1.1 

 

 

 

 

    

 

Pagina 2 van 8 

4

 

Viewing setpoint 

By pushing the SET key the setpoint appears in the display. The decimal point of the last display 
starts  blinking.  A  few  seconds  after  releasing  the  SET  key  the  setpoint  disappears  and  the 
measured temperature is shown again in the display.  

5

 

Changing setpoint 

Push the SET key and the setpoint appears in the display. Release the SET key. Now push the SET 
key again together with the UP or DOWN keys to change the setpoint. A few seconds after releasing 
the keys the measured temperature shows again in the display. 

 

6

 

Status of the relays 

By pushing the MODE key the display shows the status of the relays. Each display segment shows 
the status of the relay output, showing 0=off and 1=on. The code 110 means relay 1 and 2 are on 
and relay 3 is off. 

 

7

 

Viewing the PI-output percentage 

Push the MODE and UP keys simultaneously. Now the PI-output percentage is shown in the display. 

 

8

 

Viewing the countdown timer for forced heating 

Push the MODE and SET keys simultaneously. Now the time in hours is being displayed up to the 
next  forced  heating action.  If this  time  is  less  than  10  hours,  it  will  show  the  remaining  time  in   
hours  and  minutes  separated  by  an  decimal  point.  (representation  “h.mm”).  At  active  forced 
heating the most right decimal point is lit to indicate this. 

 

9

 

Adjustment sensor 

The temperature sensor can be adjusted by using the Sensor Offset parameter 05. 

Indicates the Sensor e.g. 2°C to much, the Sensor Offset has to be decreased with 2°C. 

Summary of Contents for ALFA(NET) 51 PI

Page 1: ...51 PI is provided with an RS 485 network connection and can be readout or set by an PC with the ALFANET program connected thru an ALFANET PC Interface 2 Installation On the connection diagram of the A...

Page 2: ...the status of the relays Each display segment shows the status of the relay output showing 0 off and 1 on The code 110 means relay 1 and 2 are on and relay 3 is off 7 Viewing the PI output percentage...

Page 3: ...on parameter P37 11 Technical data Type ALFA 51 PI 24Vdc of ALFANET 51 PI 24Vdc Range 50 50 C readout per 0 1 C Supply 24 Vdc 14 30 Vdc Display 3 digit 7 segment LED display Sensor SM 811 2 Wire PTC...

Page 4: ...larm 1 3 1 02 Function Relay 2 same as parm P01 1 3 2 03 Function Relay 3 same as parm P01 1 3 3 04 Function PI output 1 Cool 2 Heat 3 Cool and Heat 1 3 1 05 Offset temperature sensor Calibration 15 0...

Page 5: ...manual reset 0 No 1 Yes 0 40 Start up delay after power failure 0 99 Minutes 0 41 Forced relay function at sensor failure 0 None 1 Cool 2 Heat 0 2 0 60 Heat on delay 0 99 0 61 Heat off delay 0 99 0 62...

Page 6: ...ALFA NET 51 PI 24Vdc 50 50 C Doc no 150301 version 1 1 Pagina 6 van 8 13 Function diagram...

Page 7: ...ALFA NET 51 PI 24Vdc 50 50 C Doc no 150301 version 1 1 Pagina 7 van 8 14 Connections...

Page 8: ...C Doc no 150301 version 1 1 Pagina 8 van 8 15 Dimensions 16 Address VDH Products B V Tel 31 0 50 30 28 900 Productieweg 1 Fax 31 0 50 30 28 980 9301 ZS Roden Email info vdhproducts nl The Netherlands...

Reviews: