background image

3

* Adjustment sensor.

The sensor can be adjusted by using the Sensor Offset (parameter 04). Indicates
the 

ALFA(NET) 21

 e.g. 2

C too much, the Sensor Offset has to de decreased with

2

C.

* Error messages.

In the display of the 

ALFA(NET) 21

 the following error messages can appear:

Er

- Sensor broken.  Solution:

- Check if the sensor is connected correctly.
- Check the sensor (1000

 at 25

C).

- Replace the sensor.

EE

- Settings are lost.  Solution:

- Reprogram the settings.

* Technical details.

Model

: ALFA 21 Cool/Heat Thermostat
  ALFANET 21 Cool/Heat thermostat with Network

Range

: 0/+100

C, readout per 1

C

Supply

: 230 Vac 50/60Hz

Relay

: SPDT 250V/16A(C-NO), 8A(C-NC) (cos phi=1)

Control

: by push buttons on the front.

Communication

: RS485-Network   (2x twisted pair shielded, min. 0,75mm

2

)

Front

: Polycarbonate

Sensor

: SM 811/2m (1000

 at 25

C)

Demensions

: 144 x 72 x 50mm (hbd)

Panel hole

: 139 x 67mm (hb) bij doorvoer in front

- Provided with memory protection during power failure.
- Connection with screw terminals on the back side.
- Equipped with self test function and sensor failure detection.
- Special version on request available.

* Function Diagram.

Reviews: