Installation
24
VideoJet
Commissioning
with terminal program
Data terminal
You can connect a data terminal to the
VideoJet
for putting the
unit into operation and for the local control. The data terminal con-
sists of a computer with a terminal program. For the connection use
a serial standard cable.
You can use e.g. the Windows application HyperTerminal as termi-
nal program.
)
First, disconnect the
VideoJet
from the network.
)
Connect the sub-D jack CONTROL TERMINAL of the
VideoJet
to a free serial port of the computer.
Configuring the
terminal program
The transmission parameters have to match for communication
between terminal program and
VideoJet
. Set the following values
for the terminal program:
z
19,200 bits/s
z
8 data bits
z
No parity check
z
1 stop bit
z
Protocol Xon/Xoff
Note
Information on the installation and use of HyperTerminal can be
found in the documentation or in the online Help for Windows.