1.3  Specifications 

BST1918  BASE STATION TRANSCEIVER SPECIFICATIONS

 

TRANSMIT 

IF Input Frequency 

  555.0 -570.0MHz (2MHz channels) 

 

  555.2 - 569.8MHz (6MHz channels) 

Bandwidth 

 

 

Channel size: typical 6MHz, adjustable through WM404x 

IF Input Level   

 

+10 dBm nominal (total power) 

IF Detector Accuracy  

±1.0 dB typical 

RF Output Frequency Range 

Block B: 1950.0 – 1965.0MHz, (2MHz channels) 

 

               1950.2 – 1964.8MHz, (6MHz channels)

 

 

Block C: 1975.0 – 1990.0MHz,

 

(2MHz channels)

 

 

               1975.2 – 1989.8MHz, (6MHz channels) 

Frequency Response (any 6 MHz band)      

1.0 dB peak-peak 

Rated Output Power at Antenna Port 

+31 dBm (QPSK, 16QAM, 64QAM) 

Output Power Stability 

±1.0 dB over frequency and temperature 

Output Power Control Range 

20.0 to 32.0 dBm 

Output Power Control Modes 

Closed-loop on specified output power or open-loop on  

 

 

 

specified gain (compensated for IDU cable loss  

 

 

 

and temperature variations) 

Spectral Mask   

 

Compliant with FCC CFR 47 Part 24 

Phase Noise 

 

 

<-51 dBc double sideband integrated over 10 kHz to 2.5 MHz

 

MER (equalized) 

38 dB 

IF Cable Compensation Range 

15 dB 

Spectral inversion 

No spectral inversion 

 

RECEIVE 

RF Input Frequency Range 

1870-1885 MHz, Block B  

 

 

 

1895-1910 MHz, Block C 

Frequency Response (any 3 MHz band)      

0.6 dB peak-peak 

IF Output Frequency Range 

27-42 MHz 

Noise Figure at Antenna Port 

<4 dB including duplexer loss at maximum gain 

Integrated Gain  

 

55 dB nominal 

Gain Control Range   

±10 dB  

Output Third Order Intercept Point: 

+20 dBm at maximum gain 

Phase Noise 

 

 

<-95 dBc/Hz @ 10 kHz   

 

 

 

<-51 dBc double sideband integrated over 10 kHz to 2.5 MHz 

IF Detector Accuracy  

±1.0 dB typical 

Spectral inversion 

  No spectral inversion 

Image Rejection 

  > 75 dB 

 

GENERAL 

Remote Control Interface 

Bi-directional signalling with WM4040 

Connectors 

 

 

N female, 50 ohms 

Power Requirement   

-40.5 to –57VDC operational 

Power Consumption   

60W maximum 

 

 

 

Operating Temperature Range 

10°C to 40°C  

Mounting 

 

 

Standard 19” (48.3 cm), 2U (3.5”) rack space (3U in dual 

configuration) 
Dimensions  

 

 

19” (w) x 14.9” (d) x 3.5” (h) (48.3 x 37.9 x 8.9 cm) 

  

Weight  

 

 

30.8 lbs. (14kg) 

 
 
Specifications subject to change without notice. 

 

 

 

The DOCSIS

TM

 acronym belongs to CableLabs

® 

Summary of Contents for IduBST1918

Page 1: ...INSTALLATION AND OPERATION GUIDE FOR SYSTEM OPERATORS...

Page 2: ...ion and to make changes in content from time to time without obligation on the part of VCom Inc to provide notification of such revision or change VCom Inc provides this guide without warranty of any...

Page 3: ...designs and manufactures Agile CATV Modulators 256 QAM Upconverters Digital Video Modulators Frequency Translators Spread Spectrum Devices MMDS Transceivers Off Air CATV Demodulators Wireless Cable M...

Page 4: ...installer ou d op rer cet quipement lisez toutes les sections de s curit s d installations et d op rations Gardez ce manuel comme source de r f rence 2 Suivez toutes instructions si non vous risquez...

Page 5: ...ng the Unit 8 2 2 Operating Environment 8 2 3 Power Requirements 8 2 4 Rack Mounting 8 2 5 Module Installation Replacement 8 3 0 OPERATION 9 3 1 Front Panel Description 9 3 2 Operating Modes 10 4 0 RE...

Page 6: ...r in a switchover situation Low noise 4 dB including duplexer loss Digital temperature compensation to guarantee specifications over full operating temperature range All local oscillators are frequenc...

Page 7: ...Noise 51 dBc double sideband integrated over 10 kHz to 2 5 MHz MER equalized 38 dB IF Cable Compensation Range 15 dB Spectral inversion No spectral inversion RECEIVE RF Input Frequency Range 1870 1885...

Page 8: ...should be installed in a rack allowing access to the back of the unit The transceiver should be isolated from strong RF radiation emanating from local equipment in the rack 2 5 Module Installation Rep...

Page 9: ...ectly installed and enabled by the WM4040 OUTPUT ENABLED LED When the green OUTPUT ENABLED indicator is illuminated the internal output circuitry is enabled to provide an RF output The OUTPUT ENABLED...

Page 10: ...040 Remote Interface Command Transmit Frequency Tx XXXXX XXXXMHz ORF Output RF ALC Enable Disable Out RF ALC AE OR Output RF Threshold Enable Out RF Thres En TE OR Out RF Thres H S Output RF Threshold...

Page 11: ...ignaling channel 18 42 MHz or sub band for the upstream received signals 90 MHz high stability frequency reference Sub band of 555 570 MHz for the downstream transmitted signal There is active DC volt...

Page 12: ...similar to the one pictured below R M A service is available Monday to Friday from 8 30 a m to 4 30 p m CST statutory holidays excepted To obtain an R M A number you may Call 306 955 7075 press 0 for...

Page 13: ...the event that no fault is found the item is subject to the current Test Fee and will be exempt from warranty 5 Any product exhibiting external damage either from shipping improper handling or use wi...

Page 14: ...150 Cardinal Place Saskatoon Saskatchewan S7L 6H7 Canada Tel 306 955 7075 Fax 306 955 9919 www vcom com sales vcom com...

Reviews: