System Configuration
VBrick H.264 Appliance Admin Guide
31
Table 3.
Trap Summary
Authentication Password Enter password. Cannot exceed 20 characters. May include any
combination of alphanumeric characters but only the following
special characters:
~ ! # $ ^ * + & [ ] { } | < >
Authentication Protocol Select protocol: MD5 or SHA to validate the transaction
between a given host and client
Privacy Password
Required. Hides traffic using DES encryption.
Security Level
No Authentication, No Privacy (default).
No Privacy.
Authentication and Privacy.
Trap
Description
1
vbrickRemoteLog
Sent whenever a significant event occurs within
the VBrick. Each event provides details via the
vbrickSysRemoteEventLogType, and
vbrickSysRemoteEventLogText objects
2
vbrickSysTrapStartUpRunMode
Means the VBrick has started up in Run mode.
3
vbrickSysTrapStartUpDiagnosticsMode
The VBrick has started in Diagnostics mode.
4
vbrickSysTrapStartUpLimitedRunMode
Means VBrick has started in Limited Run mode.
5
vbrickSysTrapUserInitiatedReset
Means the VBrick has received a reset request
from an administrator.
6
vbrickSysTrapTemperatureOutOfRangeActive
Means the VBrick temperature is out of range.
7
vbrickSysTrapTemperatureOutOfRangeCleared
Means the out of range VBrick temperature is
recovered.
8
vbrickSysTrapUnitOverloadedActive
Means the VBrick is configured to transmit and
receive video streams beyond its capability.
9
vbrickSysTrapUnitOverloadedCleared
The overloaded VBrick is recovered to normal.
10
vbrickSysTrapPostFailure
Means that Power On Self Test (POST) failed.
11
vbrickSysTrapNetworkTimeProtocolServerDown
Means there is loss of connection to the
Network Time Protocol servers.
12
vbrickSysTrapNetworkTimeProtocolServerUp
Means there is a connection available now to the
Network Time Protocol servers.
13
vbrickSysTrapVideo1InputAlarmActive
Means that input #1 has a loss of video.
14
vbrickSysTrapVideo1InputAlarmClear
Means the loss of video on input #1 is
recovered.
15
vbrickSysTrapFanFailureActive
Means the fan failed.
16
vbrickSysTrapFanFailureCleared
Means the fan failure is recovered.
17
vbrickSysTrapAudio1InputAlarmActive
Means input #1 has a loss of digital audio.
18
vbrickSysTrapAudio1InputAlarmClear
Means the loss of digital audio on input #1 is
recovered.
Summary of Contents for 7000 Series
Page 3: ......
Page 7: ...vi Contents ...
Page 41: ...32 2009 VBrick Systems Inc ...
Page 65: ...56 2009 VBrick Systems Inc ...
Page 77: ...68 2009 VBrick Systems Inc ...
Page 83: ...74 2009 VBrick Systems Inc ...
Page 84: ......
Page 85: ...VBrick Systems Inc 12 Beaumont Road Wallingford Connecticut 06492 USA ...