background image

1. Remove the set screws (D) and to separate the mounting plate (A) from the fixture.

2. Attach the mounting plate (A) to the outlet box by using two mounting screws (B).

3. Pull the bubble glass into the fixture, and then tighten the glass screws kit (E) into the 

    holes of bubble glass.(Fig.1 Fig.2)

    

4. Pull the "U" strip into the fixture, and then tighten the screws into the holes of 

    "U" strip.(Fig.3

5. Pull out the outlet wires and house grounding wire from the outlet box. 

    Make wire connections using the wire connectors (C): 

    ---Connect the black wire from the fixture to the black wire from the power source.

    ---Connect the white wire from the fixture to the white wire from the power source.

    ---Attach the fixture grounding wire to the mounting plate with the green grounding 

       screw (F) . Then connect it to the house grounding wire with a wire connector (C).

      Carefully put the wires back into the outlet box.

6. Attach the fixture to the mounting plate (A), and then secure it with two rubber

    pads (G) and set screws (D).(Fig.4

    Note: With silicone caulking compound, caulk completely around where the 

    back plate meets with the wall surface to prevent water from seeping into the

    outlet box.

Turn off the power at fuse or circuit box

Turn on the power at fuse or circuit box

Installation Steps

181121

The following parts are available for re-order if damaged or missing. 

Spare Parts List:

A: 7”  

A

B

C

B: 13-1/2”   

C: 4”   

Assembly Kit

6042MM (1 SET) for T0496

6043MM (1 SET) for T0497

Bubble Glass

10063CS

"U" Strip

Screw

Back Plate

Fig.3

Fig.4

Fixture

Bubble Glass

Back Plate

Green Grounding Screw (F)

Rubber Pad (G)

Set screw (D) 

Mounting Screw (B)

Wire Connector (C)

Mounting Plate (A)

Glass Screw Kit (E)

Reviews: