background image

ASSEMBLY  AND  INSTALLATION 

                INSTRUCTIONS

 

 

NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements.

               2. READ AND SAVE THESE INSTRUCTIONS.

95

3

03

T

Mounting Screw (B)

Wire Connector (F)

Ball Nut (G)

Rubber Pad (H)

Cross Bar (A)

Green Grounding 

 Screw (C)

Headless

Screw (D)

WARNING:

TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF

POWER BEFORE INSTALLING OR SERVICING THIS FIXTURE.

Hardware Package (included):

IMPORTANT:

The sensor has an excellent photocell function to  enable 

the light to turn on at dusk and off at dawn automatically.

Turn off the power at fuse or circuit box

Installation Steps

1. Thread two headless screws through the cross bar, and then secure them     

    with four lock nuts. Adjust the length of the headless screws if necessary.

   

 Note: Make sure that the headless screws are lined up horizontally to make 

    

the fixture level.

2. Attach the cross bar to the outlet box by using two mounting screws.
3. Pull out the source wires from the outlet box. Make wire connections using wire connector as follows:

    ---Connect the hot wire (usually black insulation) from the fixture to the black wire from the power source.

    ---Connect the neutral wire (usually white insulation) from the fixture to the white wire from the power source.

    ---Attach the fixture grounding wire (usually green insulation or bare wire) to the cross bar with the green grounding

    screw, and then connect it to the house grounding wire with the wire connector.

    

Carefully put the wires back into the outlet box.

4. Attach the fixture body to the cross bar by inserting headless screws into holes on back plate, and then secure it with

    two rubber pads and two ball nuts.

    

NOTE:With silicone caulking compound, caulk completely around where the back plate meets with the wall

   

 surface to prevent water from seeping into the outlet box.

 

Bulb Type A Max.60W

(not included)

 

 

Back Plate

Photocell

Fixture Body

House Grounding Wire

Green Grounding Screw(C)

Fixture Grounding Wire

Wire Connector(F)

Headless Screw(D)

Outlet Box

Fixture Wire

Lock Nut(E)

Cross Bar (A)

Ball Nut (G)

Rubber Pad (H)

Mounting Screw(B)

171221

Lock Nut (E)

5. Install a bulb (not included). Check relamping label at socket area or packaging for maximum allowed wattage.

Turn on the power at fuse or circuit box.