Vaxcel T0362 Assembly And Installation Instructions Download Page 4

A

B

C

Page 4 / 4

Troubleshooting

---If the light does not work at all:

1. Make sure the wall switch and circuit breaker are on.

2. Make sure the wiring connection is correct.

3. Make sure the bulb is not burned out.

4. Cover the sensor with your palm to verify that the ambient light level is not too high.

 

----After performing 3H or 6H mode, or in 0 H mode. If the light stays on full brightness after 3 minutes. 

1. Make sure no motion could be picked up by the sensor.

2. Make sure that mode entry is not in manual override.

----In PC / Manual override Mode, if  the light stays on after dawn:

1. Whether the ambient light level is too low.

--

-

-If the light blinks: 

1. Make sure the light is not mounted near a barbecue, air conditioner or other heat source.

2. Make sure of using incandescent bulb or dimmable LED bulb.

The following parts are available for re-order if damaged or missing.

Spare Parts List:

Assembly Kit 5422MM (1 SET) 

Mounting 

Screw (B)

Set Screw 5423MM (2PCS)

Glass Panel

Glass Panel

9924CE (3PCS) 

Green Grounding 

     Screw (C)

Lock Nut (F)

Wire Nut (E)

Rubber Pad (G)

Headless 

Screw (D)

Ball Nut (H)

5-YEAR LIMITED WARRANTY:

All products are warranted to be free of defects in material and workmanship for five (5) years from date of purchase. This warranty is limited to the 

correction of any such defect, or the replacement of any such defective item(s), provided that: (a) we are properly notified and consent to return of the 

item(s) in question:(b) the item (s) is / are returned with proof of purchase date; and (c) it is found upon inspection by us that the item (s) is / are 

defective as noted above. This warranty dose not cover labor costs, consequential damages, nor dose it apply to any item(s) that have been improperly 

installed, overloaded, altered, or otherwise abused by the customer, its agent(s) or emplyee(s). Finishes are specially excluded from the terms of this 

warranty since they are subject to environmental maintenance deemed beyond our control. Other than the described obligation, we assume no further 

liability with respect to the sale or use of our products.We make no warranty, express or implied, and disclaim any warranty of merchantability or fitness

for a particular purpose.

A: 7"      

 

B: 14"     

  

C: 8-3/4"  

Mounting Plate (A)

9923CE (1PC) 

NOTE:

1. The sensitivity of the motion sensor will increase as the 

    environmental temperature gets cooler. For best performance, 

    gently clean the lens with a soft cloth every 1 or 2 months to 

    assure maximum sensitivity.
2. For best performance, install fixture at least 6 feet above the 

    ground. At such a height, the fixture will provide a detection 

    distance of up to 40 feet at 77 degrees Fahrenheit. (See Fig.5)
3. The sensor detects across a detection range of 220 degrees.

    (See Fig.6)
4. The sensor will be more sensitive to motion across its detection 

    path than motion directly towards it. (See Fig.7)
5. To reduce possible nuisances, do not mount the fixture near a 

    heat source like an air conditioner, vent or furnace exhaust, or 

    in a direction facing any reflecting object or other light source.

5`

6`

10`

40`

Where you install your lantern is important:

Be sure the light is mounted straight on the wall;

otherwise, the detection distance may be limited.

220'

Motion

Least sensitive

Motion

Most sensitive

Sensor

Fig.6

Fig.5

Fig.7

171022