0RGHV
of
Switch Control Light
:
Choose a mode by rotating the
control
switch
es
on the bottom of the fixture.
(See Fig.
2
)
.
Note: When power is first applied, the light
will initially turn on and warm
up for 30 seconds
1. Switch Control Mode
(
No network,No Linkage)
●
In "Switch Control" Mode: when the light switch is turned on, the light turn on at 100% brightness and the pre-selected
CCT color (2700K~5000K).
In "Switch Control" Mode: to change the brightness level of the light, turn the wall switch “OFF" and then back "ON"
twice within 3 seconds. The light will switch from 100% brightness to 30% brightness and pre-selected color
(2700K~5000K) or turn the wall switch OFF for 5 seconds, then turn back ON.
●
2. Motion Link Mode
●
In "Motion Link" Mode, the light will
turn
on
at
30% brightness and 2700K CCT
When the light receive
s
the motion signal:
Between Dawn to Dusk (daytime hours): the light will remain off.
Between Dusk and Early Evening hour setting on Motion Light: the light will turn on to Low Level setting (30%
brightness and 2700K CCT).
Between Early Evening setting setting on Motion Light and Dawn: the light will turn on to High Level setting (100%
brightness and 5000K CCT). When motion is no longer detected a signal will be sent to return the light to Low Level
settings (30% brightness and 2700K CCT).
At Dawn: the light will turn
off
.
3.
Unlinking from a L
ink
Group
● Press and hold the Link button on the body of light for 3 seconds,
the light will flash 3 times to exit linkage.
● In RF Link State,
shift the switch from Motion Link Mode to Switch Control Mode,
the light will return to Switch
Control function.
Page 2 / 4
Installation Steps
Turn off the power at fuse or circuit box.
Turn on the power at the main fuse or circuit breaker box.
Adjusting the Light Head:
1. Gently grasp the light heads and tilt them up or down, left or right to
adjust the light coverage area. Keep the light heads at least 1˝ (25mm)
away from the sensor.
(See Fig.
1
)
2.
Keep the light heads 30˚ below horizontal to avoid water damage and
electrical shock.
Fig.
1
1. The fixture mounting bracket is pre-assembled on the light fixture. Unscrew both the decorative cover and the fixture
mounting screw in order to remove the mounting bracket.
2. Install the mounting strap to the outlet box with the stamped word “FRONT” facing away from the outlet box, using two
mounting screws that best fit the outlet box. Mounting bracket should sit flush against wall surface when secured.
(Choose one matching pair of suitable mounting screws from the 3 pairs provided).
3.
Pull out the source wires from the outlet box. Using a 1/8” flat-head screwdriver connect the black wire from the outlet
box to the "L" interface of the terminal station on the mounting bracket. Connect the white wire from the outlet box to
the "N" interface of the terminal station on the mounting bracket. Connect the Ground wire from outlet box to "GND"
interface of the terminal station on the mounting bracket. Carefully tuck the wires back into the outlet box.
4. Place mounting bracket against the outlet box, insert the mounting bracket screw through the mounting bracket hole,
thread mounting bracket screw into the center hole of the mounting strap. Tighten the mounting bracket screw securely.
5. Attach the backplate of the light fixture to the mounting fixture mounting screw. Then push the decorative cover firmly
into the fixture mounting screw hole on the light fixture.
Tighten the fixture mounting screw securely.
6. With silicone caulking compound, caulk completely around where the back plate meets the wall surface.
CAUTION: Be sure to caulk completely where the back plate meets the wall surface to prevent water from
seeping into the outlet box.
220209
Fig.
2
2700K
5000K
Motion
Link
Switch
Control
CCT
MODE