operation

Floor/Carpet Cleaning:

Move the handle and adjust it to the desired position for
(a) storing the upright, (b) operating the cleaner (see
Fig.4/4).

NOTE: Rotating brushbar could cause the fringe of a
rug to become tangled within cleaner. Use caution and
turn off the brushbar when vacuuming throw rugs
with fringe.

Above Floor Cleaning:

Put the cleaner in the
upright position to stop
the brushroll rotating, or
simply press the brushroll
on/off button.

Remove the hose and
handle from the slot
(Fig.4/5).

Choose any of the handy
accessories or use the
hose alone. Simply push
the attachment firmly into

the end of the extension tube or hose end. To remove tool,
twist and pull apart gently.

To change the dusting brush into an upholstery tool, simply
snap off the square plastic ring housing the bristles. To
return to dusting brush for delicate surfaces (and stowable
form) simply push the ring back into place until you feel a
snap

The TurboTool is ideal for lifting pet hair off carpet, stairs
and upholstery. The TurboTool is the most effective when
using backward strokes over the area that is being cleaned.

Fig.4/5

Fig.4/3

Fig.4/6

a

b

Fig.4/4

Fig.4/7

Fig.4/8

All manuals and user guides at all-guides.com

Summary of Contents for zero turbo force z VZL-501

Page 1: ...s fully extend the mains cable before use Retain for future reference Vax careline 0870 6061248 Bagless upright Vax model number VZL 501 1 2 3 5 6 8 9 10 4 7 11 14 17 18 22 24 12 13 15 16 20 19 21 23 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...of the unit 10 Exhaust filter cover 11 Handle release pedal Step on lever to lower handle to operating or low positions 12 Carpet height adjuster Turn the carpet height adjuster to match the surface being cleaned 13 Brush bar on off indicator The indicator shows red in the Brush Bar On window then the brush bar is in operation The indicator will show red in the Brush Bar Off window when it is swit...

Page 3: ...ve liquids or vapours 13 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 14 Do not vacuum up hard or sharp objects such as glass nails screws coins etc 15 Do not use without the filters in place 16 Use extra care when vacuuming on stairs 17 Keep vacuuming area well lit 18 Store the vacuum cleaner indoors in a cool dry area 19 Turn off the switch before unpluggi...

Page 4: ... Turn the carpet height adjuster to match the surface being cleaned Fig 4 2 IMPORTANT For easiest adjustment place cleaner in full upright position WARNING The brush bar must NOT be rotating when cleaning hard floors Switch the brush bar off to prevent damage to lino parquet and other hard flooring NOTE As a precaution Vax recommends that you raise the Brush Bar as well as switching it off for use...

Page 5: ...he slot Fig 4 5 Choose any of the handy accessories or use the hose alone Simply push the attachment firmly into the end of the extension tube or hose end To remove tool twist and pull apart gently To change the dusting brush into an upholstery tool simply snap off the square plastic ring housing the bristles To return to dusting brush for delicate surfaces and stowable form simply push the ring b...

Page 6: ... the dirt container Press dirt container release button and remove dirt container from cleaner Fig 5 1 Hold dirt container over dustbin and press bin release empty button to empty Fig 5 2 Wipe inside of dust bin and shroud with a damp cloth to remove all excess dust 6 Filter Cleaning Unclip and remove the filter cover from the front of the cleaner to reveal filter cartridge Fig 6 1 Wash filter und...

Page 7: ...ve filter to dry for 24 hours before replacing in machine Debris removal TurboTool Rotate locking ring 180 and turn TurboTool over Fig 6 6 Pivot lower housing and remove clog Fig 6 7 To reassemble be sure tabs are engaged Pivot the lower housing closed then rotate the locking ring back round to secure Fig 6 8 Fig 6 4 Fig 6 5 LOCKING RING Fig 6 6 Fig 6 7 Fig 6 8 All manuals and user guides at all g...

Page 8: ...rmostat has tripped Solution Switch off and unplug the vacuum cleaner Leave for one 1 hour See page 3 PROBLEM Cleaner won t pick up loss of suction Cause Dirt container not installed properly Solution Review dirt container replacement Cause Dirt container full or blocked Solution Empty dirt container Cause Brushbar needs resetting Solution Press the brushbar reset button found just to the right of...

Page 9: ...number of the carpet cleaner before calling There are over 400 approved Vax Service Agents in the UK For the nearest Service Agent please call the Vax Careline www vax co uk 9 Technical Specification Voltage 220 240V 50Hz Wattage 1300W Capacity 2 3L Filters Foam pre motor and foam and pleated HEPA exhaust filters Cord length 7 5m Weight 10 2kg Subject to technical change without notice 9 Vax Carel...

Page 10: ...www vax co uk 10 This page has been left intentionally blank All manuals and user guides at all guides com ...

Page 11: ...11 Vax Careline 0870 606 1248 This page has been left intentionally blank All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 12: ...95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website www vax co uk All manuals and user gu...

Reviews: