Vax W85-PP-T Dual Power Pro User Manual Download Page 16

Getting in touch

What to do if it goes wrong

What to do if it goes wrong

•  Check the ‘This pack contains’ panel on the box to make sure the part 

is definitely included in your unit.

•  The plug may not be fully pushed into the electrical socket.
•  Check the fuse in the plug if this needs replacing, always replace with 

a British 13amp fuse.

•  The float in the dirty water tank may have been activated. Empty the dirty 

water tank wait for the float to settle before re-starting your carpet washer.

•  The accessory hose connector cover has not been correctly closed.  

Correctly close cover.

•  Check the SpinScrub brushes and brushbar for blockages and clear.
•  The dirty water tank may not be fitted correctly. Re-fit making sure  

the lid is pushed down securely. Go to ‘Taking care of your machine’.

•  Check the nozzle for blockages and clear. Go to ‘Taking care  

of your machine’.

•  Check the nozzle is correctly fitted. Go to ‘Taking care of your machine’.

•  Make sure the clean water tank is fitted securely. Go to ‘Using your machine’.
•  Wash/Rinse dial has been set to Rinse, set dial to wash to dispense solution.
•  The clean water tank valve may be stuck, hold the clean water tank over the 

sink and press the valve underneath to release.

•  The brushes will only spin when the carpet washer is reclined.
•  Check the SpinScrub brushes and brushbar for blockages and clear.
•  Check for damage to the brushbar and the spindle on the back of the 

SpinScrub brush cover.

Solution

Problem

CAUTION:

 To reduce the risk of personal injury, unplug the carpet washer before performing maintenance/

troubleshooting checks.

Is there an  

accessory missing?

Why won’t my carpet 

washer turn on?

Why won’t the 

solution/clean  

water dispense?

Why won’t my carpet 

washer pick up?

Why won’t the 

brushes spin?

Summary of Contents for W85-PP-T Dual Power Pro

Page 1: ...Dual Power Pro Let s get started vax co uk W85 PP T...

Page 2: ...up any flammable or combustible materials lighter fluid petrol kerosene etc or use the carpet washer in an area with explosive vapours or liquid Don t handle the plug or use the carpet washer with wet...

Page 3: ...carpet washer while it s switched on Don t attempt to remove blockages with sharp objects as this may cause damage to the carpet washer Don t use the carpet washer with incorrect voltage as this may r...

Page 4: ...ide this guide are instructions on maintaining your new machine so that it s always ready when you are to tackle your carpets Let us know what you think VaxUK Taking care of you We re here if you need...

Page 5: ...ng started Using your machine Taking care of your machine Let s talk technical What to do if it goes wrong Getting in touch Accessories Dual Power Pro Hose Included with your machine Accessory bag Spi...

Page 6: ...port hidden Solution tank cap Clean water tank cap Clean water solution tank release button Technical Specification Name Dual Power Pro Code W85 PP T Part number 1 1 134978 00 Voltage 220 240V 50Hz W...

Page 7: ...nder the legs This will prevent wood finishes from staining your carpet Pin up furniture skirts and curtains When using the carpet washer basic safety precautions should always be observed and don t o...

Page 8: ...not full then turn off your machine at the power switch and wait for the float to settle Press clean water solution tank release button pull and lift to remove tank Press clean water solution tank rel...

Page 9: ...eze the trigger to release solution and water mix Turn wash rinse dial to wash The SpinScrub brushes and brushbar deep clean your carpets with water and solution removing dirt and stains For best resu...

Page 10: ...tion into the clean water solution tank Press trigger on hose to release solution water Push hose end and hose solution connector into hose and solution connection port Fill the clean water solution t...

Page 11: ...unt of carpet cleaning solution into the clean water solution tank Push hose end and hose solution connector into hose and solution connection port Fill the clean water solution tank with warm water m...

Page 12: ...ny maintenance troubleshooting checks Lie carpet washer on its back line up squeegee with nozzle Press dirty water tank release latch pull to remove dirty water tank To re fit tilt dirty water tank an...

Page 13: ...ozzle with tabs underneath front of carpet washer Push nozzle down until it clicks into place Removing and cleaning the nozzle Using a pair of scissors remove any threads or hair caught around the bru...

Page 14: ...brushbar CAUTION Always unplug the carpet washer before performing any maintenance troubleshooting checks Changing the brushbar Lie carpet washer on its back exposing SpinScrub brushes and brushbar U...

Page 15: ...tighten x2 screws Refit and tighten screws x2 on either side of side brushes Refit SpinScrub brushes Refit rug guard pins and tighten screws Attach the other side of brushbar to side brushes Slide ont...

Page 16: ...Check the nozzle for blockages and clear Go to Taking care of your machine Check the nozzle is correctly fitted Go to Taking care of your machine Make sure the clean water tank is fitted securely Go...

Page 17: ...Getting in touch Calls are charged at the UK local rate Please make a note of the serial number and model number of the product before calling Registration required Terms and conditions apply...

Page 18: ...Ultra Carpet Cleaning Solution tackles stubborn spots and stains and removes unpleasant odours too It s specially formulated to leave no sticky residue so your carpets stay fresher for longer Ultra Re...

Page 19: ...Notes...

Page 20: ...is manufactured in compliance with the following Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disp...

Reviews: