12

troubleshooting/ uk service & help

8. UK Service & Help

Vax Care 0870 6061248

Monday-Friday

8.00am to 8.00pm.

Saturday-Sunday 9.00am to 5.00pm.

Any queries or concerns about using the Vax, call the
Vax Careline. Calls are charged at the UK national rate.

Please make a note of the serial number and model
number of the carpet cleaner before calling. There are
over 400 approved Vax Service Agents in the UK. For
the nearest Service Agent, please call the Vax Careline.

www.vax.co.uk

7. Troubleshooting

WARNING: To reduce the risk of personal injury,
unplug vacuum cleaner before servicing

.

PROBLEM: Cleaner won’t run

Cause:

Not properly plugged into wall outlet.

Solution:

Plug in firmly.

Cause:

No electricity in wall outlet.

Solution:

Check fuse or breaker.

Cause:

Blown fuse/tripped breaker.

Solution:

Reset circuit breaker or replace fuse.

Cause:

Motor thermostat tripped.

Solution:

Switch off and unplug the vacuum cleaner.
Leave for one (1) hour. See page 3.

PROBLEM: Cleaner/tools won't pick up

Cause:

Broken or worn belt.

Solution:

replace belt.

Cause:

Brush bar worn.

Solution:

Replace brush bar.

Cause:

Dirt container full.

Solution:

Empty dirt container.

Cause:

Incorrect carpet height setting.

Solution:

Move carpet height adjuster to lower setting.

Cause:

Blockage in air flow passages.

Solution:

Clear blockage.

PROBLEM: Cleaner hard to push

Cause:

Incorrect carpet height setting.

Solution:

Move carpet height adjuster to higher setting.

PROBLEM: Smoky/burning smell detected

Cause:

Belt broken or stretched.

Solution:

Replace brush bar as described in section 6.

PROBLEM: TurboTool brush bar won’t turn

Cause:

Too much pressure being applied to tool.

Solution:

Continue using tool applying light pressure.

Cause:

Blockage in turbine channel.

Solution:

Remove blockage.

Cause:

Low cleaner suction.

Solution:

Check items under “Cleaner/tools won’t pick
up” above.

!

Summary of Contents for VZL-6017 Series

Page 1: ...before using this cleaner Always fully extend the mains cable before use Retain for future reference Vax careline 0870 6061248 Bagless upright 3 1 2 15 23 14 13 12 11 10 16 17 18 19 20 21 22 4 5 6 7...

Page 2: ...itched off WARNING This machine has a rotating brush bar The brush bar must NOT be rotating when cleaning lino or hard floors Switch the brush bar off to prevent damage to lino parquet and other hard...

Page 3: ...rette butts matches or any hot smoking or burning objects 12 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours...

Page 4: ...2 Fasten 2 screws on either side of handle base Fig 3 3 Position Tools Place smaller diameter end of wand A into bottom of holder Snap wand into clip at top Repeat with other wand Crevice tool B fits...

Page 5: ...itching it off for use on lino and hard floorings Cord Rewind Grasp the end of the plug and pull to release cord from cord reel After desired cord length is reached the cord will lock into position Pu...

Page 6: ...e pedal A The indicator B will show red in the brush bar off window To turn the brush bar on step on the pedal again The indicator will show red in the brush bar on window Fig 4 8 5 Accessories Select...

Page 7: ...aning of stairs and hard to reach places Follow the steps below for attaching and detaching the Extra Reach hose Turn cleaner OFF before disconnecting and connecting hose Remove hose end from dirt duc...

Page 8: ...arch may seal the filter and cause a reduction in performance When using the cleaner for this type of dust empty the cup and clean the filters often Press dirt cup release button A and pivot cup out F...

Page 9: ...s in place Remove dirt cup as previously described Fig 6 2 With thumb and forefinger slide latch A located at the top of the housing to the right and pull down to remove gray filter frame 9 Vax Careli...

Page 10: ...turning it over The belts are located under the bottom plate of the cleaner and should be checked from time to time to be sure they are in good condition Replacing Flat Belt Replace belt if it is str...

Page 11: ...ard Fig 6 18 11 Vax Careline 0870 606 1248 maintenance Reposition bottom plate and 6 Phillips head screws Tighten screws securely Fig 6 16 Inspecting V Belt The V belt is designed to last for a long t...

Page 12: ...breaker or replace fuse Cause Motor thermostat tripped Solution Switch off and unplug the vacuum cleaner Leave for one 1 hour See page 3 PROBLEM Cleaner tools won t pick up Cause Broken or worn belt...

Page 13: ...technical specification 9 Technical Specification Voltage 230 240V 50Hz Wattage 1500W Capacity 2 6l Filters Pre motor filter assembly HEPA post motor filter Cord Length 8 3m Weight 11 8kg Subject to t...

Page 14: ...www vax co uk 14 This page has been left intentionally blank This page has been left intentionally blank This page has been left intentionally blank...

Page 15: ...15 Vax Careline 0870 606 1248 This page has been left intentionally blank...

Page 16: ...g Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle whe...

Reviews: