background image

 

vax.co.uk

3

General Safety Information 

FOR HOUSEHOLD USE ONLY. 

When using the vacuum cleaner, basic safety precautions should always

be observed, including the following:

1.

Only use the vacuum cleaner indoors on dry surfaces. Do not

handle the plug or vacuum cleaner with wet hands. Do not use

outdoors or on wet surfaces.

2.

Turn off the vacuum cleaner controls before disconnecting or

connecting from the electrical socket.

3. 

Always unplug the vacuum cleaner before connecting or

disconnecting the hose and accessories.

4.

Children should be supervised to ensure that they do not play with

the appliance.

5.

This appliance is not intended for use by persons (including

children) with reduced physical, sensory or mental capabilities,

or lack of experience and knowledge, unless they have been

given supervision or instruction concerning use of the appliance

by a person responsible for their safety.

6.

Only use as described in this manual. Only use Vax

recommended attachments.

7.

Do not use the vacuum cleaner if it has been dropped,

damaged, left outdoors or dropped into water. Do not use the

vacuum cleaner with a damaged cord or plug. If the supply

cord is damaged, it must be replaced by the manufacturer or a

recommended Service Agent to avoid hazard and 

invalidating the guarantee.

8.

Do not pull or carry by cord. Do not use the cord as a handle,

close a door on the cord or pull cord around sharp edges or

corners. Do not run the vacuum cleaner over the cord. Keep

the cord away from heated surfaces.

9.

Do not put any objects into openings. Do not use with any

openings blocked and do not restrict air flow. Keep all openings

free of dust, lint, hair or anything that might reduce airflow.

10.

Keep hair, loose clothing, fingers and all parts of the body away

from openings and moving parts.

11.

Do not pick up hot coals, cigarette butts, matches or any hot,

smoking or burning objects.

12.

Do not pick up flammable or combustible materials (lighter fluid,

petrol, kerosene etc.) or use in the presence of explosive liquids

or vapours.

13.

Do not vacuum up harmful or toxic materials (chlorine, bleach,

ammonia, drain cleaner etc.).

14.

Do not vacuum up hard or sharp objects such as glass, nails,

screws, coins, etc.

15.

Do not use without ALL of the filters in place.

16.

Take extra care when vacuuming on stairs.

17.

Keep vacuuming area well lit.  

18.

Store the vacuum cleaner in a cool, dry area.

19.

Turn off the on/off switch before unplugging the 

vacuum cleaner

20.

Use only CE-approved 13 amp extension cords.

Non-approved cords may overheat. Care should be taken to

arrange the cord so that the cord cannot be tripped over.

WARNING: 

Always switch off and unplug the vacuum cleaner from

the electrical socket before assembling, opening or emptying the dirt

container, or before connecting/disconnecting the attachments.

CAUTION:

The vacuum cleaner is a very powerful unit. Before

plugging the cord into the electrical socket, make sure the switch is in

the ‘off’ position. 

IMPORTANT:

If the inlet, hose or telescopic tube is blocked, switch off

the vacuum cleaner and remove the blockage(s) before re-starting the

vacuum cleaner. See Maintenance: 

Clearing blockages.

IMPORTANT: 

Washing filters maintains vacuum performance. Vax

recommends that they should be checked and cleaned periodically

(depending on the level of use). Make sure all filters are completely

dry before inserting back into the vacuum cleaner.

IMPORTANT: 

The motor is equipped with a thermal cut-out. If for any

reason the unit should overheat, the thermostat will automatically turn

the unit off. Should this occur, unplug the vacuum cleaner from the

electrical socket and turn off the switch. Remove dirt container and

empty. Clean filters. Allow the unit  to cool for approximately one (1)

hour. To re-start, plug into an electrical socket and switch back on.

This vacuum cleaner is intended for household use only and NOT

for commercial or industrial use.

PLEASE KEEP INSTRUCTIONS    FOR FURTHER USE.

U90 & U91-MA Air Series User Guide UPDATED 10.08.12_User guide  13/08/2012  14:17  Page 3

Summary of Contents for U9O-MA-B

Page 1: ...mber Located on the flap of the packaging What s your serial number Located on the base of the machine Note these down in case you need them in future Please keep instructions for further use e g U9O...

Page 2: ...n off button 7 Brushbar on off button 8 Inner cyclones 9 Dirt bin 10 Post motor filter release button 11 Brushbar blockage indicator 12 Brushbar access clips 13 Rotating brushbar 14 Hose to extension...

Page 3: ...le or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 13 Do not vacuum up harmful or toxic materials chlorine bleach ammonia drain cleane...

Page 4: ...instructions see page 6 IMPORTANT Do not use the vacuum cleaner without all of the filters in place 1 2 17 22 15 6 2 7 Twist cord hook to release cord Turn unit on Adjust handle height Recline unit Br...

Page 5: ...tension tube Attach accessory to telescopic extension tube IMPORTANT Hold unit while using hose or telescopic extension tube 17 22 Attaching to hose Attaching to telescopic extension tube 23 Choose an...

Page 6: ...filter Cleaning the HEPA pre motor filter tap tap 24hr tap Advanced cleaning 1 2 40 C max 1 2 WARNING Do not wash the post motor filter Maintenance Keep your Vax as good as new 6 U90 U91 MA Air Serie...

Page 7: ...debris from the brushbar If the light continues to flash red after resetting the brushbar may still be blocked Using a pair of scissors cut through any threads or hairs caught around the brushbar To a...

Page 8: ...ccessory becomes damaged or broken We re here to help Simply call 0844 412 8455 or visit vax co uk Why won t the accessories pick up properly Hose blockages remove the hose from the unit Carefully rem...

Page 9: ...parts helps to maintain optimised performance and validates your guarantee Filter kit Type 27 1 9 129220 00 Technical Specification Voltage 220 240V 50Hz Wattage 1200 W Capacity 1 5L Filters Pre moto...

Page 10: ...ce with the following Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household wast...

Page 11: ...Notes vax co uk 11 U90 U91 MA Air Series User Guide UPDATED 10 08 12_User guide 13 08 2012 14 17 Page 11...

Page 12: ...ion 1 1 Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website vax co uk U90 U91 MA Air Series User Guide UPDATED 10 08 12_User guide 13 08 2012 14 17 P...

Reviews: