11
Vax Careline
0870 606 1248
maintenance
Remove brush bar including end plates (A) and discard.
Inspect belt to ensure that it is in good condition. If belt
is cracked, gouged or broken, replace it (see following
section).
Insert brushbar through belt and position belt over gear
teeth (B) on brushbar (Fig.6/12).
With curved ends down, slide end plates (A) of brushbar
into slots (B) on too (Fig.6/13).
Replace belt guard (A) making sure not to pinch brush
bristles in guard. Turn brush bar, to make sure it rotates
freely (Fig.6/14).
Replace and tighten screws.
To replace bottom plate, insert the four tabs on edge of
bottom plate into slots on front of tool.
Pivot bottom plate down and snap closed (Fig.6/15).
Powered Hand Tool Belt Replacement
The powered hand tool belt is designed to last a long
time and is not normally replaced. However, if the belt is
cracked, gouged or broken, it should be replaced.
Remove tool from hose. The belt can be seen through the
top of the nozzle or by removing the bottom plate and
belt guard (Fig.6/16).
Remove tool from hose. Remove bottom plate, belt guard
and brushbar as described previously.
Grasp turbine (A) and pull firmly to remove. Remove belt
from turbine pulley (B). Replace with new belt (Fig.6/17).
Fig.6/12
Fig.6/13
Fig.6/15
Fig.6/16
Fig.6/17
Fig.6/14
A
B
A
A
B
B