Vax Mach Air SERIES User Manual Download Page 3

 

FOR HOUSEHOLD USE ONLY. 

When using the vacuum cleaner, basic safety precautions

should always be observed, including the following:

1.

Only use the vacuum cleaner indoors on dry 

surfaces.

2.

Turn off the vacuum cleaner controls before

disconnecting or connecting from the mains supply.

3. 

Always unplug the vacuum cleaner before

connecting or disconnecting the vacuum hose and

accessories.

4.

Children should be supervised to ensure that they

do not play with the appliance.

5.

This appliance is not intended for use by persons

(including children) with reduced physical, sensory

or mental capabilities, or lack of experience and

knowledge, unless they have been given supervision or

instruction concerning use of the appliance by a

person responsible for their safety.

6.

Use only as described in this manual. Use only Vax

recommended attachments.

7.

Do not use the vacuum cleaner if it has been

dropped, damaged, left outdoors or dropped into

water. Do not use the vacuum cleaner with a

damaged cord or plug. If the supply cord is damaged, it 

must be replaced by the manufacturer or a 

recommended Service Agent to avoid hazard and 

invalidating the guarantee.

8.

Do not pull or carry by cord/hose. Do not use the 

cord/hose as a handle, close a door on the cord/hose 

or pull cord/hose  around sharp edges or corners. Do 

not run the vacuum cleaner over the cord/hose. Keep 

the cord away from heated surfaces.

9.

Do not handle the plug or vacuum cleaner with wet

hands. Do not use outdoors or on wet surfaces.

10.

Do not put any objects into openings. Do not use

with any openings blocked and do not restrict air-

flow. Keep all openings free of dust, lint, hair or

anything that might reduce airflow.

11.

Keep hair, loose clothing, fingers and all parts of

the body away from openings and moving parts.

12.

Do not pick up hot coals, cigarette butts, matches

or any hot, smoking or burning objects.

13.

Do not pick up flammable or combustible 

materials (lighter fluid, petrol, kerosene etc.) or use 

in the presence of explosive liquids or vapours.

14.

Do not vacuum up harmful or toxic material

(chlorine, bleach, ammonia, drain cleaner etc.).

15.

Do not vacuum up hard or sharp objects such as

glass, nails, screws, coins, etc.

16.

Do not use without ALL of the filters in place.

17.

Take extra care when vacuuming on stairs.

18.

Keep vacuuming area well lit.  

19.

Store the vacuum cleaner in a cool, dry area.

20.

Turn off the on/off switch before unplugging the 

vacuum cleaner

21.

Use only CE-approved 13 amp extension cords.

Non-approved cords may overheat. Care should 

be taken to arrange the cord so that the cord 

cannot be tripped over.

WARNING: 

Always switch off and unplug the

vacuum cleaner from the electrical outlet before

assembling, opening or emptying the dirt container, or before

connecting/disconnecting the attachments.

CAUTION:

The vacuum cleaner is a very powerful

unit. Before plugging the cord into the electrical

outlet, make sure the switch is in the ‘off’ position. 

IMPORTANT:

If the inlet, hose or telescopic tube

is blocked, switch off the vacuum cleaner and

remove the blockage(s) before re-starting the vacuum

cleaner. See Maintenance; Clearing Blockages.

IMPORTANT: 

Cleaning filters maintains vacuum

performance. Vax recommends that your filters

should be checked and cleaned periodically. If your filters are

washable make sure they are completely dry before

inserting back into the vacuum cleaner.

IMPORTANT: 

The motor is equipped with a thermal

cut-out. If for any reason the unit should overheat,

the thermostat will automatically turn the unit off. Should this

occur, unplug the vacuum cleaner from the electrical outlet

and turn off the switch. Remove dirt container and empty.

Clean filters. Allow the unit  to cool for approximately one (1)

hour. To re-start, plug into an electrical outlet and switch back

on.

This vacuum cleaner is intended for household use

only and NOT for commercial or industrial use.

PLEASE KEEP INSTRUCTIONS    FOR FURTHER USE.

!

General Safety Information 

!

!

!

!

vax.co.uk

3

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U89 U90 & U91-MA Mach Air UG V2.1(V7):User guide  18/03/2011  16:50  Page 3

Summary of Contents for Mach Air SERIES

Page 1: ...number Located on the base of the machine Note these down in case you need them in future Please keep instructions for further use Mach Air Series User Guide Vax Careline UK 0844 412 8455 ROI 1 800 928 308 e g U91 MA B U89 U90 U91 MA Mach Air UG V2 1 V7 User guide 18 03 2011 16 50 Page 1 ...

Page 2: ...connector 15 Quick release cord wrap 16 Cord 17 3 in 1 crevice upholstery and dusting brush tool 18 Wheels 19 Hose to machine connector 20 Brushbar reset button 21 Hose 22 Flexi crevice tool not standard on all models 23 Flat nozzle upholstery tool not standard on all models NOTE Some parts may vary according to model Please check inside flap of box for more details 23 22 25 28 24 Telescopic exten...

Page 3: ...e materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 14 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 15 Do not vacuum up hard or sharp objects such as glass nails screws coins etc 16 Do not use without ALL of the filters in place 17 Take extra care when vacuuming on stairs 18 Keep vacuuming area well lit 19 Sto...

Page 4: ...or full cleaning instructions see page 6 IMPORTANT Do not use the vacuum cleaner without all of the filters in place 1 2 Twist cord hook to release cord Adjust handle height Turn unit on Recline unit Brushbar on carpets Brushbar off hard floors IMPORTANT Switching the brushbar on whilst cleaning hard floors may damage flooring Vax Careline UK 0844 412 8455 ROI 1 800 928 308 U89 U90 U91 MA Mach Air...

Page 5: ...ic extension tube Attach accessory to telescopic extension tube IMPORTANT Hold unit while using hose or telescopic extension tube Attaching to hose Attaching to telescopic extension tube Choose an accessory Using the stretch hose Not standard on all models Remove stretch hose Attach stretch hose to hose Attach stretch hose to telescopic extension tube U89 U90 U91 MA Mach Air UG V2 1 V7 User guide ...

Page 6: ...iner Cleaning the post motor filter Cleaning the HEPA pre motor filter tap tap 24hr tap Advanced cleaning 1 2 40 C max 1 2 WARNING Do not wash the post motor filter Vax Careline UK 0844 412 8455 ROI 1 800 928 308 U89 U90 U91 MA Mach Air UG V2 1 V7 User guide 18 03 2011 16 50 Page 6 ...

Page 7: ...will indicate a jammed brushbar To reset press the button on the side of your vacuum Removing debris from the brushbar If the light continues to flash red after resetting the brushbar may still be blocked Using a pair of scissors cut through any threads or hairs caught around the brushbar To access brushbar Press the brushbar reset button again to ensure the blockage is fully cleared IMPORTANT for...

Page 8: ...ls only Slide off the locking ring Pivot lower housing and remove clog To re assemble ensure that the tabs are engaged and pivot the lower housing closed Slip the locking ring into the groove at the neck of the TurboTool to complete reassembly Tabs U89 U90 U91 MA Mach Air UG V2 1 V7 User guide 18 03 2011 16 50 Page 8 ...

Page 9: ...essory the unit becomes damaged or broken Visit vax co uk for parts and spares Please call our Vax Careline to purchase new spares or order a replacement 0844 412 8455 Why won t the accessories pick up properly The accessory may be blocked Refer to the Maintenance section page 7 The accessory may be faulty please call our Vax Careline to order a replacement 0844 412 8455 Why will the vacuum cleane...

Page 10: ...or visit vax co uk Consumables To purchase spares and accessories please visit vax co uk Filter kit 1 9 129220 00 Stretch hose 1 9 130429 00 Technical Specification Voltage 220 240V 50Hz Wattage 1200 W Capacity 1 5L Filters Pre motor filter washable HEPA post motor filter tap to clean not standard on all models Antibacterial HEPA post motor filter tap to clean not standard on all models Cord lengt...

Page 11: ...d in compliance with the following Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice U89 U90 U91 MA Mach Air UG V2 1 V7 User guide 18 03 2011 16 50 Page 11 ...

Page 12: ... Version 2 0 Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website vax co uk U89 U90 U91 MA Mach Air UG V2 1 V7 User guide 18 03 2011 16 50 Page 12 ...

Reviews: