background image

12

10.

DIAGNOSING PROBLEMS/TROUBLESHOOTING

Problem

Possible cause

Remedy

The pull-out is not dampened
when it closes.

The height setting of the plastic part 
on the inner guide rail’s door link
bracket is incorrect.

Set the height of the plastic part on the inner 
guide rail’s door link bracket according to the
HSA installation manual.

The pull-out does not close 
completely when actuated 
slowly.

The height setting of the plastic part 
on the inner guide rail’s door link
bracket is incorrect.

Set the height of the plastic part on the inner 
guide rail’s door link bracket according to the
HSA installation manual.

HSA rotary:
The pull-out opens too fast.

Wrong setting of the DIP switch.

Check and, if necessary, adjust the DIP switch
setting (see section 4, HSA rotary installation).

The pull-out only opens a little
bit.

Wrong setting of the DIP switch.

Check and, if necessary, adjust the DIP switch
setting (see section 4, HSA rotary installation).

The pull-out does not always
open when pressed.

The drive unit’s trigger pin is not set
correctly.

Readjust the drive unit’s trigger pin 
(see section 6).

Summary of Contents for HSA power move

Page 1: ...44007523_01 Operating and installation manual Important document for the end customer HSA power move 11 2010 068 HSA rotary power move ...

Page 2: ...4 3 FEATURES 5 4 INSTALLATION HSA and HSA rotary 5 7 5 ELECTRICAL CONNECTIONS 8 6 FUNCTIONAL DESCRIPTION OPERATION 9 7 SYMBOLS USED 10 8 TYPE PLATES 10 9 TECHNICAL DATA 10 10 DIAGNOSING PROBLEMS TROUBLESHOOTING 11 12 11 CLEANING AND MAINTENANCE 13 12 DISPOSAL 13 13 MATERIAL DEFECTS AND PRODUCT LIABILITY 13 ...

Page 3: ...s plug or connection mains cable mains adapter must be accessible so that the mains adapter can be disconnected from the power supply The system must be made currentless by removing the plug from the mains socket before any monitoring repairs or cleaning are carried out on the system The system must not be used if damaged Never open the mains adapter or the drive unit fatal danger through electric...

Page 4: ...screw 5 x 20 3 x Self locking hexagon nut M5 1 x Nut holder Ejection lever Countersunk screw M5 x 10 1x Mains adapter bracket Spax countersunk screw 4 x 16 2 x Mains adapter cable length 1 5 m output side Mains cable length 2 m 1 4 7 12 11 10 9 8 6 5 3 2 1 4 12 11 10 9 3 2 8 5 6 7 7 HSA HSA rotary ...

Page 5: ... dependent on load Triggering of the opening impulse by lightly pulling or pressing the cabinet front Front clearance can be set on the drive Minimisation of noise transmitted to the corpus thanks to rubber dampers Interruption of the slide out movement in the event of a blockage If power fails the tall cabinet can be used like a normal non supported tall cabinet 4 INSTALLATION HSA Building out th...

Page 6: ...6 4 INSTALLATION HSA Ejection lever and drive unit 1 2 3 288 32 29 109 93 77 32 Ø 20 mm 349 3 x 5 x 20 mm 10 5 19 Ø 5 5 1 2 ...

Page 7: ...7 3 x 5 x 20 mm 4 INSTALLATION HSA rotary 288 32 98 109 95 79 32 Ø 20 mm 418 1 2 ...

Page 8: ...HSA and HSA rotary Note Only insert the mains plug after all the components have been installed correctly and all the other connections have been set up The system may only be connected to the mains voltage specified in section 9 ...

Page 9: ...hat can be set using a cross slot screwdriver Pressing or pulling the front actuates the trigger pin and triggers the opening impulse The spindle on the drive unit moves the pull out out with a controlled movement into the opened position and moves straight back into the final position The pull out can subsequently be closed 1600 x x x x x x P 1600 ...

Page 10: ...maximum of 1 minute permanent operation With shorter operating times the intermittent times can be reduced in the same ratio Symbol for the observance of standards and regulations that are relevant for the prescribed proper use 9 TECHNICAL DATA Mains adapter Mains voltage AC 100 240 V 50 60 Hz Output DC 24V 2 5A 60W Outer dimensions W60 H38 L120 Drive unit Supply voltage 24V Power max 30W Type of ...

Page 11: ...pull out opens when pulled but not when pressed There is an object between the cabinet front and the corpus Remove the object The distance between the cabinet front and the corpus is set too small Set the distance between the cabinet front and the corpus larger see section 6 The guide profiles have been displaced Reference the guide again push the fitting in firmly to the end stop Door buffer The ...

Page 12: ...inner guide rail s door link bracket is incorrect Set the height of the plastic part on the inner guide rail s door link bracket according to the HSA installation manual HSA rotary The pull out opens too fast Wrong setting of the DIP switch Check and if necessary adjust the DIP switch setting see section 4 HSA rotary installation The pull out only opens a little bit Wrong setting of the DIP switch...

Page 13: ...od s proper use The customer s right of recourse against the manufacturer on account of such claims of material defect liability which are made against the ordering party by its clients is excluded if the customer does not fulfil his examination and notice of non conformity The customer may only use the goods for the proper purpose and must make sure that the goods are only re sold to people who a...

Page 14: ...Vauth Sagel Neue Straße 27 D 33034 Brakel Erkeln Telefon 49 5272 601 01 Fax 49 5272 601 193 Internet www vauth sagel de ...

Reviews: