DIAGNOSING PROBLEMS/TROUBLESHOOTING
Problem
Possible cause
Remedy
The pull-out is not dampened
when it closes.
The height setting of the plastic part
on the inner guide rail’s door link
bracket is incorrect.
Set the height of the plastic part on the inner
guide rail’s door link bracket according to the
HSA installation manual.
The pull-out does not close
completely when actuated
slowly.
The height setting of the plastic part
on the inner guide rail’s door link
bracket is incorrect.
Set the height of the plastic part on the inner
guide rail’s door link bracket according to the
HSA installation manual.
HSA rotary:
The pull-out opens too fast.
Wrong setting of the DIP switch.
Check and, if necessary, adjust the DIP switch
setting (see section 4, HSA rotary installation).
The pull-out only opens a little
bit.
Wrong setting of the DIP switch.
Check and, if necessary, adjust the DIP switch
setting (see section 4, HSA rotary installation).
The pull-out does not always
open when pressed.
The drive unit’s trigger pin is not set
correctly.
Readjust the drive unit’s trigger pin
(see section 6).