6.

 

Installation / end of work 

Preparing the gun for the first start-up: Screw in the compressed air connection 
and tighten it firmly with a 13 mm open-end or ring spanner, if necessary glue 
it in place.  

With  optional pressure regulator instead  of air volume regulation

: Screw the 

pressure gauge included in the extent of delivery into the pressure regulator, if 
necessary glue it in place. 
Start  up:  Unscrew  the  pressure  container  and  fill  the  medium  into  the  con-
tainer. Then hand-tighten the gun with the container cover onto the pressure 
container. Do not use any tools for this! Plug the connection nipple of the hose 
(type 3900 or 3901) onto the quick coupling and let it engage. Connect the gun 
to the compressed air supply via the quick coupling of the air connection. By 
pressing the trigger you put the pressure cup gun into operation. 
 

Attention:  

Wear  heat-resistant  gloves  when  using  heated 
medi-um. Danger of burns!

  

 

 

The spray pattern can be influenced by the following factors: 

 

Material quantity via stop screw/nozzle needle 

 

Adjusting the intake pressure (optional) 

 

Distance between hand spray nozzle and object 

 

Angular position of the hand spray nozzle to the object 
 

End of work: 

Vent the pressure container by turning the pressure container 

counterclockwise. 

Disconnect the device from the compressed air supply after 

each use. Empty the pressure container. Clean the device according to the in-
structions given in point 7.  
 

Attention:  

Never operate  the trigger while the container is under pres-
sure but the pressure  cup  gun is not  connected to the com-
pressed air source. This can push the medium into the air ducts 
and render the pressure cup gun unusable! 

 

7.

 

Maintenance and care 

Clean the compressed air device after each use. Empty the pressure container 
and blow out the pressure cup  gun and the hoses by putting the device into 
operation. If you want to clean the pressure cup gun with cleaning medium, we 
recommend benzine or commercially available turpentine-based cleaning me-
dium. 

Do not use aggressive cleaners!

 Following the maintenance instructions 

will ensure a long service life and trouble-free operation for this quality product. 
 

Summary of Contents for 3300 DPF

Page 1: ...OPERATING MANUAL 3300 DPF V6 4 20 EN Page 1 Cleaning pressure cup gun 3300 DPF Art no 33140 33158 ...

Page 2: ...ting manual with the pressure cup gun General notice This pressure cup gun was developed for certain applications We explicitly point out that this pressure cup gun must not be modified and or used in a way that does not correspond to its intended use Content 1 Technical data 3 2 Extent of delivery 3 3 Intended use 3 4 Features 3 5 Safety instructions 3 6 Installation end of work 5 7 Maintenance a...

Page 3: ...y included with 3300 DPF set Hose set 3900 WH 02 04 3 Intended use This pressure cup gun is a compressed air operated quality tool for professional use It is suitable for processing liquid media in the form of loose containers 4 Features The effectiveness of the 3300 DPF pressure cup gun is based on overpressure For this purpose pressure is built up in the pressure container by means of an air duc...

Page 4: ...rom the compressed air connection before carrying out maintenance or repair work Only use original spare parts The maximum working pressure must not be exceeded see point 1 Technical data The working pressure must be adjusted via a filter pressure reducer Only use compressed air as energy source The compressed air connection may only be made via quick coupling When working with the pressure cup gu...

Page 5: ...ced by the following factors Material quantity via stop screw nozzle needle Adjusting the intake pressure optional Distance between hand spray nozzle and object Angular position of the hand spray nozzle to the object End of work Vent the pressure container by turning the pressure container counterclockwise Disconnect the device from the compressed air supply after each use Empty the pressure conta...

Page 6: ...n clogged parts Air exits the spray nozzle even though the trigger is in its initial position Possible cause Valve bolt is jammed Solution Pour oil onto the valve bolt and or into the compressed air intake Operate the trigger several times Material exits the spray nozzle even though the trigger is in its initial posi tion Possible cause Nozzle needle is jammed dirty Solution Clean the nozzle needl...

Page 7: ... gun must be in its original condi tion 11 Address In case of service your sales representative is at your side or contact the follow ing address Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach Germany Telephone 49 0 2774 80069 0 E Mail info vaupel gmbh de Internet www vaupel gmbh de Notice We reserve the right to make technical changes Illustrations may differ f...

Page 8: ...rdance with the above EC Directives under the general responsibility of Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The following harmonised standard has been applied DIN EN ISO 12100 Sicherheit von Maschinen Allgemeine Gestaltungsleit sätze Risikobeurteilung und Risikominderung The operating manual belonging to...

Page 9: ...OPERATING MANUAL 3300 DPF V6 4 20 EN Page 9 13 Notices ...

Page 10: ...OPERATING MANUAL 3300 DPF V6 4 20 EN Page 10 14 Technical drawing ...

Page 11: ...on 16 60 4100 364 O ring 5 x 1 mm 17 30 1421 012 Needle gland 18 60 4100 366 O ring 8 x 2 5 mm 19 30 1422 014 Nozzle head 20 20 1413 001 Quick coupling 21 See accessories list Cavity spray hose accessory 22 83313 O ring 15 x 2 mm 23 Adapter 3000 25 O ring 33 x 2 mm 26 10 2111 014 Cup holder 27 60 4100 344 U cup 12 x 18 x 4 5 x 1 6 28 60 4100 387 O ring 35 x 4 mm 29 30 83309 Fixing screw 31 10 4102...

Reviews: