Protect yourself and the environment by taking appropriate precautions against 
the risk of accidents and observe the following instructions in your own inter-
est: 

 

 

The operator must ensure proper operation. 

 

 

Do not bring compressed air and/or medium into contact with 

skin or eyes. 

 

Never direct the spray jet at animals, people or yourself. 

 

Keep children and pets away from the operating area. 

 

No manipulations, emergency repairs or misappropriations 
may be carried out on the pressure cup gun. 

 

Pressure cup guns may only be operated and maintained by 
instructed persons.  

 

Repairs must only be carried out by qualified persons. 
 

The following applies to all maintenance and repair work:

  

 

It  is  essential  to  disconnect  the  pressure  cup  gun  from  the 
compressed air connection before carrying out maintenance 
or repair work. 

 

Only use original spare parts. 

 

The  maximum  working  pressure  must  not  be  exceeded  (see 
point  1  "Technical  data").  The  working  pressure  must  be 
adjusted via a (filter) pressure reducer. 

 

Only use compressed air as energy source. 

 

The compressed air connection may only be made via quick 
coupling. 

 

When working with the pressure cup gun, wear the necessary 
protective clothing, protective goggles, work gloves, ear pro-
tection if necessary and a respirator mask. 

 

If there are leaks in the device or other operating faults, the 
device must be disconnected from the compressed air supply 
immediately and the cause of the fault must be eliminated. 

 

Open fire, sparks or smoking is prohibited. 

 

Beware of flammable materials. 

 

Processed media and cleaning media must be disposed of in 
an environmentally friendly manner. 

 

The disposal of the compressed air device must be carried 
out according to the valid legal regulations. 

 
 
 

Summary of Contents for 3300 DPF

Page 1: ...OPERATING MANUAL 3300 DPF V6 4 20 EN Page 1 Cleaning pressure cup gun 3300 DPF Art no 33140 33158 ...

Page 2: ...ting manual with the pressure cup gun General notice This pressure cup gun was developed for certain applications We explicitly point out that this pressure cup gun must not be modified and or used in a way that does not correspond to its intended use Content 1 Technical data 3 2 Extent of delivery 3 3 Intended use 3 4 Features 3 5 Safety instructions 3 6 Installation end of work 5 7 Maintenance a...

Page 3: ...y included with 3300 DPF set Hose set 3900 WH 02 04 3 Intended use This pressure cup gun is a compressed air operated quality tool for professional use It is suitable for processing liquid media in the form of loose containers 4 Features The effectiveness of the 3300 DPF pressure cup gun is based on overpressure For this purpose pressure is built up in the pressure container by means of an air duc...

Page 4: ...rom the compressed air connection before carrying out maintenance or repair work Only use original spare parts The maximum working pressure must not be exceeded see point 1 Technical data The working pressure must be adjusted via a filter pressure reducer Only use compressed air as energy source The compressed air connection may only be made via quick coupling When working with the pressure cup gu...

Page 5: ...ced by the following factors Material quantity via stop screw nozzle needle Adjusting the intake pressure optional Distance between hand spray nozzle and object Angular position of the hand spray nozzle to the object End of work Vent the pressure container by turning the pressure container counterclockwise Disconnect the device from the compressed air supply after each use Empty the pressure conta...

Page 6: ...n clogged parts Air exits the spray nozzle even though the trigger is in its initial position Possible cause Valve bolt is jammed Solution Pour oil onto the valve bolt and or into the compressed air intake Operate the trigger several times Material exits the spray nozzle even though the trigger is in its initial posi tion Possible cause Nozzle needle is jammed dirty Solution Clean the nozzle needl...

Page 7: ... gun must be in its original condi tion 11 Address In case of service your sales representative is at your side or contact the follow ing address Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach Germany Telephone 49 0 2774 80069 0 E Mail info vaupel gmbh de Internet www vaupel gmbh de Notice We reserve the right to make technical changes Illustrations may differ f...

Page 8: ...rdance with the above EC Directives under the general responsibility of Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The following harmonised standard has been applied DIN EN ISO 12100 Sicherheit von Maschinen Allgemeine Gestaltungsleit sätze Risikobeurteilung und Risikominderung The operating manual belonging to...

Page 9: ...OPERATING MANUAL 3300 DPF V6 4 20 EN Page 9 13 Notices ...

Page 10: ...OPERATING MANUAL 3300 DPF V6 4 20 EN Page 10 14 Technical drawing ...

Page 11: ...on 16 60 4100 364 O ring 5 x 1 mm 17 30 1421 012 Needle gland 18 60 4100 366 O ring 8 x 2 5 mm 19 30 1422 014 Nozzle head 20 20 1413 001 Quick coupling 21 See accessories list Cavity spray hose accessory 22 83313 O ring 15 x 2 mm 23 Adapter 3000 25 O ring 33 x 2 mm 26 10 2111 014 Cup holder 27 60 4100 344 U cup 12 x 18 x 4 5 x 1 6 28 60 4100 387 O ring 35 x 4 mm 29 30 83309 Fixing screw 31 10 4102...

Reviews: