6
© Copyright 2010 Vauni AB - All rights reserved
4. A sa
fety distance of at least 20 mm behind all the fi re box’s sides, which creates an air column to
allow effi
cient cooling, as well as to avoid direct contact with fl ammable objects.
Installa• on
without
fi re box:
(Figure 9A + B)
Burner OF must be ins
talled in a fi xed and secure posi! on before it is put into use – see the
instruc! ons below. The base must be fl at and smooth, and made of a non-fl ammable material such as
stainless steel, minerite, bricks, cement or stone. The fi re source must be in a draught-free place with
no risk of curtains or loose objects coming within one metre of the source. The following minimum
safety distances apply for installa! on without a fi re box:
Behind:
min 90 mm between the unit and the back wall (of non-fl ammable material)
In front:
min 90 mm between the unit and the front edge
Sides:
min 450 mm free space from the unit’s edge, and no fl ammable material within 1
metre
Above:
min 1500 mm safety distance – do not place any object above the fi re source within
this distance. Non-fl ammable objects can be placed more than 1500 mm above the
base.
Base:
Of non-fl ammable material(s).
2 burners:
min 50 mm free space between the units’ edges. (Figure 9B)
Now that the burner is completely assembled, read
Sec• on 4 Firing for instruc• ons
on how to start it
the fi rst ! me.