USER MANUAL
Vauconsant SA, all rights reserved A625xx -rev0-ENG, 14/10/2010 - 8 -
Maintenance
Always remember to
switch off
the appliance by opening the fuse holder before any
maintenance operations.
•
Bain-marie well:
Lift the well from the unit. The heating
elements are accessible by dismantling the
ventilation duct inside the well by pulling it
upwards.
•
Ventilated heat cupboard:
The heating module is placed on the heat cupboard’s ceiling. To dismantle it, remove the 4
mounting screws fixing it to the ceiling. The ventilator is fixed by 3 screws, the heating elements are
fixed by 2 nuts, use a Ø19 flat spanner to remove them.
Ventilation deflector
Heating
elements fixing
sheet
Heating elements sheet
support
Ventilator support
Casing
Heating elements
Ventilator
Well
Blowing conduct
Ventilator
Heating elements