background image

Technical information VERSO VA-IP2 – V1.0 

 

 

p.4/13 

 

 

 

Information and RECOMMENDATIONS 

 

o  Pursuant to European directive UTE C00-200, incorporating directives 89/336 EEC and 

92/31 EEC, VERSO complies with the following standards: 

•  NF EN 50081-1 governing electromagnetic radiation, and 
•  NF EN 50082-1 governing electromagnetic susceptibility. 

Cabling recommendations:

 the cables used to connect readers, the network and other 

peripherals must be installed in accordance with the instructions for Level 2 (protected 
environment) of standard NF EN 61000-4-4. 

This product must be installed by an approved company.

 Incorrect installation and use may 

result in electric shock or fire. Before installation, read the technical information and comply with 
the recommendations for assembling the product. 

For the 220V version, once the power is turned off, all the internal capacitors will discharge 
themselves to a safe level after 60 seconds under normal conditions. However, in the event 
of a power failure, the charge may be maintained for much longer and suitable precautions 
should be taken before handling the product. 

 

 

 

 

Summary of Contents for VA-IP2

Page 1: ...Technical Information VA IP2 VERSO 220...

Page 2: ...N 5 CONNECTING A DEVICE USING THE wiegand or clock data protocol 6 CONNECTING V EXT4 AND V EXT4 220 modules 7 CONNECTING A POWER LOSS BOLT AND AN ELECTROMAGNETIC DOOR LOCK OPERATING ON POWER LOSS 8 CO...

Page 3: ...hased a VERSO VA IP2 unit manufactured by the French company Vauban Systems exclusively distributed by Eos Australia for the Australian and New Zealand markets We thank you for your interest in our pr...

Page 4: ...ordance with the instructions for Level 2 protected environment of standard NF EN 61000 4 4 o This product must be installed by an approved company Incorrect installation and use may result in electri...

Page 5: ...2V 1A 24V 2 VERSO 220 Weight with housing 4 kg Housing dimensions 330 x 275 x 80 mm Operating temperature 20 C to 50 C Integrated 220V power supply Output voltage 12V Maximum output current F2 5A F1 6...

Page 6: ...higher Note Each reader can have different technology e g Reader 1 using Wiegand Reader 2 using Clock Data Warning If you use an external power supply for your proximity readers take care to connect...

Page 7: ...erminals on the V EXT4 modules to connect an RS485 bus Information 2 conductors 2 pairs recommended Max distance 750 m Cable type 0 6 mm SYT recommended Warning Do not install the cables near other hi...

Page 8: ...ay interfere with proper system operation due to back currents it is imperative to use and connect the anti back current diodes supplied with the unit in compliance with the cabling diagram above Even...

Page 9: ...er system operation due to back currents it is imperative to use and connect the anti back current diodes supplied with the unit in compliance with the cabling diagram above Even when using an additio...

Page 10: ...fferent IP address you can use the Automatic detection menu in VISOR To do this proceed as follows After having created your installation on first start up VISOR offers to create a new unit Click on t...

Page 11: ...andard FREE Dongle required Up to 840 readers VISOR 840 available as an option Dongle required Installation of dongle with the power off install the dongle as shown below To confirm proper operation V...

Page 12: ...Technical information VERSO VA IP2 V1 0 p 12 13 FUNCTIONS OF THE TERMINALS Reset switch 1 Reset switch 2 Ethernet network RS485 extension bus...

Page 13: ...55 0 Turn off the power Hold the switch down while turning the power back on Wait until the relays engage about 20 seconds holding the switch down Release the switch Use this switch to clear the unit...

Reviews: