3 Operation 

For user information and recommendations for pressure control please refer to ch0r ‘9.4 User Information and Recommendations’ 
 
Display Information: (PM-4 with Service Box only)

 

 
‘P1:’/’P2:’ for actual pressure, ‘SP:’ for set point pressure, ‘Pos:’ for valve position (0000 = closed, 1000 = open) 

Errors:  
‘E’ on display for  position error, ‘P‘ for parameter error  (refer to section ‘6 Trouble Shooting’) 

Power-fail option: 
‘D’,
 if power-fail option disabled temporarily (only in local mode possible) 

Logic Inputs: 
‘M’,
 if Logic Inputs disabled by RS232C command 
 
 

3.1  Local Mode (PM-4 with Service Box only) 

Activate keyboard:  
Press «LOCAL» key for 2 seconds to enable keyboard. LED on «LOCAL» key will turn green. 

Open valve:  
Press «OPEN». LED on «OPEN» key will turn green. 

Close valve:  
Press «CLOSE». LED on «CLOSE» key will turn green.  

Select sensor:  (for double sensor version) 
Press «F2» & «

» key to toggle between sensor 1 and sensor 2. As an alternative, the sensor setup may be used to select the sensor for 

pressure control. 

Pressure control:  
Press «PRESSURE MODE» key, then press one of the four «SET POINT» keys. Use «

» or «

» key to change set point value. Store the 

set point value by pressing one of the four «SET POINT» keys for at least 2 seconds. 

Freeze valve position, interrupt pressure control:  
While in PRESSURE MODE, press «F1» key to interrupt pressure control and freeze the actual valve position. ‘HOLD’ will appear on 
display. Press «PRESSURE MODE» key to continue pressure control. 

Valve position control:  
Press «POSITION MODE», then press one of the four «SET POINT» keys. Use «

» or «

» key to change the position value. Store set 

point value by pressing «SET POINT» key for at least 2 seconds. 

Note:  Commands «ZERO», «LOCAL», «REMOTE», «LEARN», «F1» & «F2» require that the keys are pressed for 2 seconds, before 

the commands are accepted to prevent that the settings are changed accidentally. 

Contrast of the display can be adjusted by pressing «F1» & «F2» & «

», or «F1» & «F2» & «

» key. 

 
 

 

3.2  Remote Mode (PM-5 if Interface installed only) 

Press «REMOTE» key for 2 seconds or select remote operation through RS 232C or LOGIC interface for remote control. For details about 
interface wiring and remote commands refer to chapter ‘9 Engineering Information’. 
 
 

3.3  Power Failure / Power Failure Option (PFO) 

All parameters will remain stored during a power failure. 

If a power-fail battery is installed (check VAT part number of PM controller: 641PM- . 6B . - . . . .), the PM controller has to be hooked up to 
power for at least 10 hours to assure repeated valve closures in case of a power failure. 

Note: By 

pressing 

the 

«F2» key for 2 seconds, the Power Fail Option will be disabled for 1 minute. A ‘D’ will be displayed on the 

control panel. 

 

Summary of Contents for PM-4

Page 1: ...641P 6 Read these Installation Operating and Maintenance Instructions IOMI and the enclosed General Safety Instructions carefully before you start any other action Table of content 1 Intended Use of P...

Page 2: ...ranges specified below 1 1 Technical Data Mains voltage 100 240 VAC 10 50 60 Hz Temperature 0 50 C Sensor input signal 0 10 VDC max Sensor power supply 15 VDC 5 1400 mA max total current for sensor 1...

Page 3: ...apter 9 1 2 Connector for mains 5 Interface cable wiring information see chapter 9 1 3 Connector for interface 6 Sensor 1 standard and 2 option 7 Cable for sensor 1 and 2 wiring information see chapte...

Page 4: ...your system is higher than 1 of sensor full scale Evacuate process chamber to high vacuum When the base pressure is reached send RS232 command Z CR LF see 9 3 1 Control commands or use Logic command...

Page 5: ...Use or key to change set point value Store the set point value by pressing one of the four SET POINT keys for at least 2 seconds Freeze valve position interrupt pressure control While in PRESSURE MOD...

Page 6: ...new expiration date on back panel of PM controller Perform PM configuration routine SENSOR SETUP AUTO SIZE ADJUST ZERO LEARN IC3 SRAM IC3 Socket Power fail battery this is an option which is installed...

Page 7: ...y powered SRAM memory ROM ER displayed EPROM defective to be changed LED on CLOSE key is flashing valve is closed and does not respond to RS 232 or keyboard commands Logic CLOSE input on RS 232 interf...

Page 8: ...diately following delivery thereof by VAT provided that the same is properly operated under conditions of normal use and that regular periodic maintenance and service is performed or replacements made...

Page 9: ...or signal 8 Sensor signal 10 15 VDC max 5 1400 mA max 12 0 VDC 14 15 VDC max 5 1400 mA max total current for both sensors is 1400mA Mind Do not connect other Pins than indicated in the table above Rec...

Page 10: ...closed or open as long as the contact is closed Close has higher priority than open 5 DISABLE LOCAL Contact closed PM controller is switched into remote mode key pad LOCAL is disabled as long as cont...

Page 11: ...t Valve is open when contact between PIN 8 and 10 is closed 70V 0 5 A max 9 CLOSE VALVE output Valve is closed when contact between PIN 9 and 10 is closed 70V 0 5 A max 10 Common for digital output 70...

Page 12: ...tion for details If 2 nd command acknowledgement is enabled the PM controller will send a second acknowledgement after the command has been executed Example C CR LF command will close valve The PM con...

Page 13: ...28 CR LF 428 1 1000 of stroke Zero adjust Sensor offset adjustment Z CR LF Z CR LF Automatic zero adjustment Learn up to maximum pressure to be learned in 1 1000 of sensor full scale L 00xxxx CR LF L...

Page 14: ...logic inputs from RS232 are active Control mode M CR LF M POS CR LF M PRESS CR LF POSITION MODE PRESSURE MODE Self test T CR LF T ____OK CR LF T PAR ER CR LF T ROM ER CR LF memory o k parameter error...

Page 15: ...bar 2 Torr 3 mTorr 4 Pa 5 kPa 6 V 7 8 0001 1000 9 none A Position Mode only 2 pressure display in Torr d Gain Factor 0 1 00 1 1 33 2 1 78 3 2 37 4 3 16 5 4 22 6 5 62 7 7 50 8 0 1 9 0 13 A 0 18 B 0 23...

Page 16: ...mode or with S Command Pressure control starts after PRESSURE MODE and a SET POINT is selected or after a pressure control command is sent to the PM controller 9 4 2 How to optimize sensor signal res...

Reviews: