Installation, Operating & Maintenance Instructions
Series 75.0, DN 63-200 CF-F (I.D. 2½“- 8")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected]
www.vatvalve.com
280717EA
2009-03-05
5/12
Radiation resistance
- Shutter
Standard
10
5
Gy (10
7
rad)
Radiation resistant 10
6
Gy 10
6
Gy (10
8
rad)
-
Actuator
Standard
10
4
Gy (10
6
rad)
Radiation resistant 10
5
Gy 10
5
Gy (10
7
rad)
- Position indicator
Standard
10
4
Gy (10
6
rad)
Radiation resistant 10
6
Gy 10
6
Gy (10
8
rad)
Compressed air connection
R
1
/
8
“ (
1
/
8
“ NPT for USA)
Compressed air pressure (overpressure)
5 – 8 bar / 70 – 110 psig
Solenoid (opening)
- Supply voltage
24V DC
- Power required
2.5 W
Closing time (DN63/100/160/200)
<
13 / 15 / 23 / 40 ms (response time of sensor is not included)
Opening time
7 s
Weight (DN63/100/160/200)
28 / 32 / 36 kg / 39kg // 62 / 70 / 80 / 86 lbs
2 Installation
2.1 Unpacking
Caution! dirt sensitive product. Touching the product or parts thereof with bare hands increases the desorption
rate.
Always wear clean lint-free gloves and use clean tools when working in this area.
2.2 Installation into the system
The valve must not support other components and has to be protected from forces of the system (e.g. by bellows
sections).