background image

Installation, Operating & 
Maintenance Instructions 

 

 

 

1003735EB.DOCX 

Edition 2020-01-08 

 

 

Control Angle Valve 

 
 

Series 620 
DN 100 (I.D. 4") 

 
This manual is valid for the following product ordering numbers 
 

62040-QE52-…. 
62040-XE52-…. 

 

 

Sample picture 

 

Summary of Contents for 620 Series

Page 1: ...Operating Maintenance Instructions 1003735EB DOCX Edition 2020 01 08 Control Angle Valve Series 620 DN 100 I D 4 This manual is valid for the following product ordering numbers 62040 QE52 62040 XE52 S...

Page 2: ...ms duplicated or distributed without written permission from VAT Offenders are liable to pay damages The original VAT firmware and updated state of the art versions of the VAT firmware are intended fo...

Page 3: ...8 3 2 Function of valve 8 4 Installation 9 4 1 Unpacking 9 4 2 Installation of valve into the system 10 4 2 1 Installation example chamber pump preferred layout 11 4 2 2 Installation procedure 12 4 3...

Page 4: ...Use product for clean and dry vacuum applications only Other applications are only allowed with the written permission of VAT 1 3 Used abbreviations Abbreviation Description CPA Control Performance An...

Page 5: ...hrottle open Closing opening 1 000 000 200 000 Admissible operating temperature 10 C to 80 C Mounting position Any Process side materials body Stainless steel 316L 1 4404 plate Stainless steel 316L 1...

Page 6: ...lation Operating Maintenance Instructions are an integral part of a comprehensive documentation belonging to a complete technical system They must be stored together with the other documentation and a...

Page 7: ...RNING Unqualified personnel Inappropriate handling may cause serious injury or property damage Only qualified personnel are allowed to carry out the described work 2 4 Safety labels Label Part No Loca...

Page 8: ...Valve seat side 3 2 Function of valve The valve plate acts as a throttling element and varies the conductance of the valve opening The controller calculates the required plate position to achieve the...

Page 9: ...that the supplied products are in accordance with your order Inspect the quality of the supplied products visually If it does not meet your requirements please contact VAT immediately Store the origi...

Page 10: ...oller or power supply Connect all cables exactly as shown in the following schematic NOTICE Burned connector pins spark Connector pins or electronic parts could damage if plugged and unplugged under p...

Page 11: ...Series 620 INSTALLATION 1003735EB DOCX Edition 2020 01 08 11 26 4 2 1 Installation example chamber pump preferred layout Sample picture Chamber Pump Control angle valve 1 Valve cable 3 Controller 2...

Page 12: ...Follow recommendation of chain clamp manufacturer The valve seat side is indicated by the symbol Refer to chapter Design or dimensional drawing Do not admit higher forces to the valve than indicated...

Page 13: ...valve body Forces from the weight of other components can lead to deformation of the valve body and to malfunction of the valve Do not higher force the valve body as specified The following forces ar...

Page 14: ...vers of heating device are closed and no parts under voltage could be reached CAUTION Valve opening Risk of injury Do not operating before the valve is installed complete into system CAUTION Hot valve...

Page 15: ...stem await until the valve is cooled down complete 25 C before doing any work NOTICE Damage during heat up ramp and cool down If valve is closed and fan not running then valve may get damaged Make sur...

Page 16: ...is deactivated and valve is in open position before starting service procedure One maintenance procedure is defined for this valve Replacement of plate seal bonnet seal and valve cleaning Required fr...

Page 17: ...ench No 6 Clean room wiper Isopropyl alcohol O ring removal tool see chapter Accessories Description Required tool 1 Obey the safety advice 2 Open the valve 3 Switch OFF PFO 4 Switch OFF power to the...

Page 18: ...ked with isopropyl alcohol 10 Install the new bonnet and plate O rings For new O rings refer to chapter Spare parts 11 Assemble actuator unit with bellows into valve body in reverse order 12 Fasten th...

Page 19: ...Repairs may only be carried out by the VAT service staff In exceptional cases the customer is allowed to carry out the repairs but only with the prior consent of VAT Please contact one of our service...

Page 20: ...lve may get damaged Make sure that valve is in open position and fan running NOTICE Contamination Gate and other parts of the valve might have been contaminated during usage Always wear protective glo...

Page 21: ...humidity between 10 and 70 temperature between 10 C and 50 C non condensing environment NOTICE Inappropriate packaging Product may get damaged if inappropriate packaging material is used Always use t...

Page 22: ...he VAT form Declaration of Chemical Contamination and send it to VAT in advance The form can be downloaded from our website www vatvalve com If products are radioactively contaminated the VAT form Con...

Page 23: ...amage in the case of improper handling Observe local regulations in regard to waste disposal without fail Commission an authorized waste disposal company for the professional disposal of your waste NO...

Page 24: ...20 01 08 1003735EB DOCX 11 Spare parts 11 1 Overview Item Description Part No 1 Plate seal FKM e g Viton 216210 2 Bonnet seal FKM e g Viton N 5100 253 Bellows unit 1007115 11 2 Accessories Description...

Page 25: ...Series 620 1003735EB DOCX Edition 2020 01 08 25 26 12 Appendix...

Page 26: ...Series 620 26 26 Edition 2020 01 08 1003735EB DOCX This Page Intentionally Left Blank...

Reviews: