Description
Required tool
12. Lubricate seal contact surface of
shaft with a slight film of vacuum
grease (0.0125 ml).
13. Slide both o-rings onto shaft till the
end.
14. Deposit 0.0375 ml vacuum grease
between the o-rings
15. Clean shaft from vacuum grease.
Mount
mechani
cal
uni
t to val
v
e
bod
y
16. Assemble mechanical unit in reverse
order as disassembled (steps 6 to
5).
17. Align pedestal parallel to valve body
and tighten the 2 mounting screws
with 2 Nm.
Allen Wrench
3mm