background image

Operation Cont’d 

Touchscreen Controls 

Set your exposure cycle by selecting either 
ENTER TIME or SELECT PRESET on the home 
screen.  Your machine has the ability to save 
and recall up to 10 presets, storing exposure 
times.   

Setting the exposure time: 

1) From the setup screen press the number

under the label EXPOSURE .

2) Enter a time from 0-999 seconds.
3) Press DELETE enough times to enter the

desired time.

4) Press ENTER to confirm selection.

Running an exposure cycle: 

1) From the setup screen, select RUN to start

the exposure cycle.

2) The remaining exposing time is shown on

the run screen.
To end the cycle at any time, select
CANCEL.  Pressing CANCEL will return to
the setup screen.

3) After completing a cycle, EXPOSURE

COMPLETE will be displayed.  Press OK to
return to the setup screen.

Home Screen 

Setup Screen 

Exposure Screen 

Press to enter time 

Return to home screen 

Press to run 

Press to save preset 

Run Screen 

Pg.5

Summary of Contents for E2-CTS-2536

Page 1: ...rnational Inc 7 Emery Street Bethlehem Pa 18015 USA Phone 610 625 2702 Fax 610 625 2775 Web Site www vastex com Authorized Representative in Europe Certification Experts BV Nieuwstad 100 1381 CE Weesp...

Page 2: ...2536 Overall Size lid closed Depth x Width x Height 20 5 x 31 6 x 56 4 52 1cm x 80 4cm x 143 2cm Weight 140 lbs 63 5 kg Screen Capacity 25 x 36 Power Requirements 100V 125V 60Hz 3 0 Amps 200V 240V 50...

Page 3: ...clear of the work area Do not store any objects on top of the exposing unit Unplug power cord before entering control box Do not operate if any guard or cover has been removed Do not operate if power...

Page 4: ...osure Time A full and complete exposure will be effected by several variables listed by importance 1 Type and brand of emulsion 2 Thickness of stencil qty of coats or capillary film thickness 3 Mesh c...

Page 5: ...ELETE enough times to enter the desired time 4 Press ENTER to confirm selection Running an exposure cycle 1 From the setup screen select RUN to start the exposure cycle 2 The remaining exposing time i...

Page 6: ...or messages EXPOSURE INCOMPLETE POWER FAILURE A power failure occurred during an exposure cycle Loss of power to the unit or from the power supply will trigger this error If the error occurs during th...

Page 7: ...working If not proceed to step 3 contact factory for replacement light It may be possible to expose screens with LED lights out but a repair is needed to ensure optimal performance Light Bar Replacem...

Page 8: ...remove the top 8 nut holding down the light bar 6 Installing the new light bar Seat the light bar in its corresponding slot and attach the connector 7 Test the new light bar See above step 2 8 Secure...

Page 9: ...tio will prevent a good gasket seal prevent good detail resolution and increase chances of saw tooth edges Manufacturers recommend an EOM ratio of 10 to 20 percent With an emulsion stencil more is not...

Page 10: ...st Rz numbers possible and can save large amounts of screen room production time Fig 6 Capillary films are best applied with the emulsion up on a hard flat surface Fig 7 Fig 7 Place a screen squeegee...

Page 11: ...licensed trucker shall constitute delivery to Buyer and be determinative of the date and time of shipment and all risk of loss or damage in transit shall be borne by Buyer If the Buyer fails to accept...

Page 12: ...Pg 12...

Reviews: