Storage
MAC R motors can be stored for long periods (up to 2 years) without their specifications being affected. They
must be stored in a dry, dust-free place with no aggressive atmosphere or vibrations and no sudden temperature
changes.
PRECAUTION
Damages caused by outdoor storage
The machine may be damaged if it is stored outdoors.
The machine must be stored only in indoor areas that meet the following conditions:
-
It must be dry, dust-free, frost-proof and have no vibrations. The relative humidity of the air must be
below 60%; in accordance with EN 60034-1, the temperature must not be below -15ºC.
-
It must be well ventilated.
-
It must provide protection against extreme bad weather.
-
The ambient air must not contain aggressive gases.
The machine must be protected against knocks and humidity and its entire surface must be appropriately
covered.
If the machine cannot be stored in a dry place, the following measures must be adopted:
-
Cover the machine using a plastic film or similar with a drying material (silica gel) inside.
-
Package the unit in a sealed box.
-
Place several bags of drying agents in the sealed box. Check the drying product regularly and replace it
as necessary.
-
Control the humidity level in the sealed packaging by placing indicators that show the air humidity level
in the packaging at different levels.
If the machine is to be stored for a relatively long period (more than 6 months), it must be checked regularly
(every 3 months) to ensure that it is in a perfect state of repair and that there are no faults. The required
maintenance work must be carried out and the storage enclosure must be climate-controlled.
PRECAUTION
Damage caused by condensation water
Condensation water may gather in the machine owing to important variations in ambient temperature, direct
sunlight or high air humidity levels during storage.
If the stator winding is damp, its insulation resistance is reduced. This leads to disruptive discharges that can
destroy the winding. Furthermore, condensation water may form oxide or mould inside the machine.
This is why it is important to follow VASCAT's storage recommendations to the letter.