background image

19.0” C1-D2 Compliant Panel Mount PC 

 

 486-0032-0-00 

3

Safety Instructions 
 
PLEASE NOTE - This equipment is suitable for use in Class I, Division 2 or non-hazardous 
locations only.  
 
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS 
BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS. 
 
AVERTISSEMENT - RISQE D'EXPLOSION - AVANT DE DECONNECTER L'EQUIPMENT, COUPER 
LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON DANGEREUX. 

 

  Read the Safety Instructions carefully and keep it for use later. 

 

  The chassis metalwork of the module must be installed properly to the main earthing termination 

for Class 1 equipment. 

 

  Care must be exercised in the application of the system to prevent overheating. Ensure that the 

ambient temperature around the system does not exceed 60°C and provide adequate means of 
ventilation to achieve this. 

 

  When cleaning cut off the electrical supply at all times. Never use liquid or aerosol detergent, 

use a soft damp cloth instead. 

 

  Never insert anything metallic into the chassis openings. This may create an electric shock 

hazard or hazard from rotating fan blades. 

 

  To avoid electric shock, never touch the inside of the system. There are no user adjustable 

components inside, only a qualified technician should open the system’s case. 

 

  Openings in the system enclosure are to allow for ventilation. To prevent overheating, these 

openings should not be blocked or covered. 

 

  If the system does not operate normally – in particular, if there are any unusual sounds or smells 

coming from it – disconnect it immediately. 

 

  Do not put pressure on the LCD/LED panel screen because it is very fragile. 

 

  Always handle the system with care when moving it. 

 

  Take care that the system is disposed of correctly at the end of its life. If in doubt refer to your 

local ordinances or regulations for proper disposal. 
 

  User to supply appropriate lockable type plug and power disconnecting switch. 

 

  The end user must either supply a switch to their power outlet suitable for Class 1, Division 2 

use (if adjacent to the power outlet), or locate the said switch outside the hazardous area. 
 

  This equipment is suitable for use in a Class 1, Division 2, Groups A, B, C, and D or non-

hazardous location only. 

Summary of Contents for VTPC900PSS

Page 1: ...manding Applications VARTECH S Y S T E M S I N C 19 0 Class 1 Division 2 Compliant Panel Mount PC Model VTPC900PSS User s Guide Read these instructions completely before attempting to operate your new...

Page 2: ...19 0 C1 D2 Compliant Panel Mount PC 486 0032 0 00 2 Revision History Date Rev No Summary Page 10 12 09 00 First Issue 02 12 10 01 Added French Language...

Page 3: ...lic into the chassis openings This may create an electric shock hazard or hazard from rotating fan blades To avoid electric shock never touch the inside of the system There are no user adjustable comp...

Page 4: ...ardous locations Do not disconnect equipment unless power has been switched off and area is known to be non hazardous Do not connect or disconnect components unless power has been switched off All wir...

Page 5: ...esigned or rated for those specific environmental conditions that will be present and designed to prevent personal injury resulting from accesibility to live parts These units are shipped with a gaske...

Page 6: ...ipe with a damp lint free cloth and blow on it to dry Do not clean the panel with a keton type material e g acetone or ethyl toluene ethyl acid methyl or chloride These may damage the LCD LED panel Do...

Page 7: ...Expansion Slots Dual PCI Back Panel I O Ports PS 2 Keyboard Connector x 1 PS 2 Mouse Connector x 1 Power Inlet x 1 RS 232 Port x 3 x1 422 485 Optional USB 2 0 Port x 6 x4 on Stainless Steel Models RJ...

Page 8: ...ax Power Consumption 68W Temperature Operational 32 F to 140 F 0 C to 60 C Storage 4 F to 149 F 20 C to 65 C Humidity Operational 20 to 40 C 90 RH NC Storage 5 to 65 C 28 RH NC Installation of Your Pa...

Page 9: ...closure using the lock nuts and washers supplied with the unit behind the holes running along the sides and the top and bottom of the cutout in the panel Extra lock nuts and washers are provided 4 Tig...

Page 10: ...19 0 C1 D2 Compliant Panel Mount PC 486 0032 0 00 10 Panel Mount Drawing Detail A Connections to the Panel Mount PC Bottom Rear View AC unit shown Connector Panel...

Page 11: ...g to their power outlet Also the end user must either supply a switch to their power outlet suitable for Class I Division 2 use if adjacent to the power outlet or locate the said switch outside the ha...

Page 12: ...it is highly recommended that the system be properly shut down and power turned off when the Panel Mount PC is not in use LCD Monitor Warm up Time All LCD LED monitors need time to become thermally st...

Reviews: