Fiscal module FM3000
6/33
www.varos.sk
switch base Default DTR/DSR.
SW4
- output voltage for opening of the cash drawer
For supply voltage of fiscal module 12V
CLOSE 1-2 - voltage 24V for the cash drawer
CLOSE 2-3 - voltage 12V for the cash drawer
For supply voltage of fiscal module 24V
CLOSE 1-2 -
*** Do not use this option, it can destroy rectifier doublet ***
CLOSE 2-3 - voltage 24V for the cash drawer
Default CLOSE 1-2.
SW5
- Fiscal module supply from USB port. If is the module supplied from USB port, connector for
cash drawer opening is out of function.
If fiscal module is not supplied from USB port, SW5 has to be opened !
OPEN - fiscal module is supplied from external source.
CLOSE - fiscal module is supplied from USB port of computer
Default OPEN.
SW6
- Input of 5V voltage supply to 9 pin of connector LPT_RS232.
OPEN - 9 PIN of the connector is not connected
CLOSE – the 5V voltage input on 9 PIN of the connector
Default OPEN.
SW7
- Data flow managing on virtual serial port that created by USB driver in computer during
communication of the fiscal module through USB port.
CLOSE 1-2 - DTR/DSR
CLOSE 2-3 - RTS/CTS
Default CLOSE 1-2.
INPUT - Options for data input: from RS232 or USB port.
It is necessary adjust jumpers according to the legend on switch base.
USB input is possible to use for operation systems Apple OS-8, OS-9 and OS-X,
Linux Kernel 2.4.0 and higher, Windows 98 / ME / 2000 / XP, Open BSD version 3.2 and
higher, Free BSD version 4.7 and higher. Default RS232.UT - RS232
KON1 - Connector for connection fiscal module with extending input/output module.
LED - After voltage connection fiscal module performs its auto test of proper functionality of
particular internal components. Tests check connection of the
printer for printing receipts.
If printer does not respond or is offline, fiscal module does
not respond any command
.
LEDs indicate mode of fiscal module. During the test are LEDs on in compliance with running test. After
the tests finish LED diodes indicates status of fiscal module.
ON - LED is on, OFF – LED is off
LED1
LED2
LED3
Condition of fiscal module FM3000
ON
OFF
ON
The MMC memory does give any response or is not initialised.
OFF
ON
OFF
Normal situation. Module is OK printer is connected.
ON
OFF
OFF
Timer error.
ON
ON
OFF
Printer is in mode BUSY. Test is performed before each printing.
OFF
ON
ON
EEPROM memory does not respond.
OFF
OFF
ON
Loading of the turnover from issued receipts in MMC memory.
ON
ON
ON
The MMC memory formatting or burning new BIOS.
During the MMC memory formatting computer screen shows
message MASTER RESET ZAC. After formatting ended screen
shows text MASTER RESET END. After BIOS burning shows text
FLASH.