Before  fastening  the  hose  to  the  pump,  it  is  best  to  fill  it  with  water  first.  After  this  you  can 
screw the three-way cock or another  25mm (1")  connector to the outlet on the pump; this is 
on the top of the pump. 
Then you should fill the pump housing with water through the build-in filter; then re-seal it. 
If the pump housing and the hose have both now been filled with water, you can switch on the 
pump using the on/off switch. The pump now immediately begins to pump water (in the case 
of  the  auto  version,  the  pressure  tank  is  first  filled  and  it  takes  a  few  seconds  before  water 
comes out of the connected hose). 
If  the  pump  is  subsequently  switched  off  again,  water  remains  in  the  pump  housing  and  the 
hose which means that when the pump is next switched on it will pump water immediately. 
If  no  non-return  valve  is  fitted  or  if  the  seal  between  the  valve  and  the  hose  is  not  working 
properly (hose clip!) the whole unit may run dry again and must be re-filled to get the pump to 
work properly. 

7.1 

Pressure hose 

The pressure hose is used for conveying the  water from the pump to the water consumption 
point  (e.g.  tap,  etc.).  In  order  to  minimize  the  friction  loss  caused  by  the  water  pressure,  we 
recommend that you use a pressure hose with a minimum diameter of 20mm (3/4"). 

 

When the garden pump is working, the water outlet (e.g. tap or water sprinkling outlet) 
must be open so as to discharge the air from the hose. If the water outlet is closed, the 
pump may be damaged due to overheating of the pump after working for more than 5 
minutes. 

 

Freezing of the pump or placing it in a frosty space in the winter must be avoided. 

 

Sand and stones in the water taken in can rapidly wear the pump and reduce its effective 
capacity. It is therefore necessary to install a filter. 

 

This water pump is not suitable for long-term operation, e.g. in industrial or mining 
enterprises or for a water recycling system. 

7.2 

Safety requirements 

 

The power supply must comply with the specifications displayed on the product. Refer to 
the instructions of your local energy supplier if necessary for connecting conditions. If the 
pump or the power cable do not comply, do not connect the pump! 

 

Never carry the pump by the cable. 

 

Never remove the plug and never shorten the cable. If you do, you will invalidate your 
guarantee. Keep the connection (plug and socket) dry. 

 

The pump is not suitable for use in swimming pools and lakes or other situations where 
persons could come into physical contact with the water, and must therefore not be used 
for this purpose. 

 

Always disconnect the pump from the power supply when cleaning it or carrying out 
maintenance to the pond. This pump is suitable for pumping water with a minimum 
temperature of 4 °C and a maximum temperature of 35 °C. 

 

The pump must not run dry, as this will cause irreparable damage. 

 

Always disconnect the pump from the mains supply before cleaning or maintenance. 

 

Clean  the chambers from time to time, rinsing them with clean water, to ensure they are 
not clogged with dirt. 

 

 

Summary of Contents for Powerplus POWXG9571

Page 1: ...ST 2 4 SYMBOLS 2 5 SPECIFIC SAFETY WARNINGS 3 6 ASSEMBLY 3 6 1 Electrical connection 3 6 2 Earth 3 7 OPERATION 3 7 1 Pressure hose 4 7 2 Safety requirements 4 8 CLEANING AND MAINTENANCE 5 8 1 Cleaning...

Page 2: ...accessories for transportation damages Keep the packaging materials as far as possible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packing m...

Page 3: ...lation of the equipment it is necessary to keep it under dry and well ventilated conditions at an ambient temperature below 40 C If the required pumping water is excessive due to your own action resul...

Page 4: ...o as to discharge the air from the hose If the water outlet is closed the pump may be damaged due to overheating of the pump after working for more than 5 minutes Freezing of the pump or placing it in...

Page 5: ...ump is experienced guaranteed repairs must be carried out by an authorized maintenance center Never use solvents such as petrol alcohol ammonia water etc These solvents may damage the plastic parts 9...

Page 6: ...p sprinkling nozzle etc The waiting time does not correspond to the regulations Fill the whole suction hose with water or recheck it at least 7 minutes after the pump starts Excessive suction head 8m...

Page 7: ...t of transportation Damage and or defects resulting from inappropriate use also do not fall under the warranty provisions We also disclaim all liability for any bodily injury resulting from inappropri...

Page 8: ...LGIUM declares that Product Pressure Pump 600W 19l House Trade mark POWERplus Model POWXG9571 is in conformity with the essential requirements and other relevant provisions of the applicable European...

Reviews: