Important Note!
If the mains cable or plug suffers any damage from external action, repairs to the cable should
be serviced by a qualified specialist using only standard spare parts. This will ensure that it
meets the required safety standards.
8 SETTING TO WORK
After having read these instructions carefully, you can set your pump to work, reconsidering
the following:
▪
Check if the pump rests on the ground of the shaft.
▪
Check of pressure cord has been attached properly.
▪
Check if electrical connection is 230 V - 50 Hz.
▪
Check if socket is in good condition.
▪
Make sure that water and humidity can never come to the mains supply.
▪
Avoid pump running dry.
8.1
Venting the pump before use
▪
Always ensure that the pump is vented properly before commissioning the pump. Possibly
tilting back and forth several times until no more air bubbles appear, wait at least 15
seconds before the pump to start.
This appliance cannot be used by children or people who are physically, mentally or
developmentally impaired, or people who lack experience or knowledge, except in case
these people receive instruction from a person responsible for their safety, a
supervisor, or by studying the preceding instructions concerning use of this appliance.
8.2
Build-in floating switch
▪
When the switch is on the top (manual), pump will be running continuously without
stopping. User has to move the switch down or plug off to stop the machine (Fig. 1).
▪
When the switch is at ‘Automatic’ position, the pump will start when water level is above
12 cm (Fig. 2).
9 CLEANING AND MAINTENANCE
Attention! Before performing any work on the equipment, pull the power
plug.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
9.1
Maintenance guidelines
This submersible pump is an approved, maintenance-free high quality product, which is
subject to severe final controls. We recommend regular inspection and maintenance to ensure
long equipment life and uninterrupted operation.
Important! Note!
Remove the mains plug before all maintenance work.
▪
When the pump is often transported in the course of operation, it should be cleaned out
with clear water after every use.
▪
In case of stationary installation, the function of the bating switch should be checked every
3 months.
▪
All fibrous particles which may have built-up inside the pump housing should be removed
with a water jet.
▪
Every 3 months the shaft ground and as should be cleaned from mud.