4  SYMBOLS 

In this manual and/or on the machine the following symbols are used: 

 

Read manual before use 

 

In accordance with essential 
requirements of the European 
directive(s) 

 

Class  II  -  The  machine  is 
double 

insulated; 

Earthing 

wire 

is 

therefore 

not 

necessary. 

 

Wear ear guards and goggles 

 

Denotes risk of personal injury 
or damage to the tool. 

 

Wear gloves 

5  GENERAL POWER TOOL SAFETY WARNINGS 

Read  all  safety  warnings  and  all  instructions.  Failure  to  follow  all  warnings  and  instructions 
may  result  in  electric  shock,  fire  and/or  serious  injury.  Save  all  warnings  and  instructions  for 
future reference. The term "power tool" in the warnings refers to your mains operated (corded) 
power tool or battery operated (cordless) power tool. 

5.1 

Work area 

 

Keep work area clean and well lit. Cluttered and dark areas invite accidents. 

 

Do not operate power tools in explosive atmospheres, such as in the presence of 
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or 
fumes. 

 

Keep children and bystanders away while operating a power tool. Distractions can cause 
you to lose control.  

5.2 

Electrical safety 

Always  check  that  the  power  supply  corresponds  to  the  voltage  on  the 
rating plate. 

 

Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any 
adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching 
outlets will reduce risk of electric shock. 

 

Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges 
and refrigerators. There is an increased risk of electric shock if your body is earthed or 
grounded. 

 

Do not expose power tools to rain or wet conditions. Water entering a power tool will 
increase the risk of electric shock. 

 

Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power 
tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled 
cords increase the risk of electric shock. 

 

When operating a power tool outdoors, use an extension cord suitable for outdoor use. 
Use of a cord suitable for outdoor use reduces the risk of electric shock. 

 

If operating a power tool in a damp location is unavoidable, use a residual current device 
(RCD) protected supply. Use of an RCD reduces the risk of electric shock. 

5.3 

Personal safety 

 

Stay alert, watch what you are doing and use common sense when operating a power 
tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol or 

Summary of Contents for PowerPlus POWE10060

Page 1: ...ADDITIONAL SAFETY INSTRUCTIONS FOR HAMMER DRILLS 4 7 BEFORE USING THE TOOL FOR THE FIRST TIME 5 7 1 Fitting and changing tools Fig 2 5 7 2 Removing SDS plus tool 5 8 OPERATION 6 8 1 Switching ON OFF 6 8 2 Handle attachment Fig 3 6 8 3 Depth stop 6 8 4 Dust collection device Fig 4 6 8 5 Hammer drill switch 6 9 CLEANING AND MAINTENANCE 7 9 1 Cleaning 7 10 TECHNICAL DATA 7 11 NOISE 7 12 SERVICE DEPAR...

Page 2: ...p 7 On off switch 8 Depth stop 9 Handle 10 Carbon brush cover 11 Power On LED light 3 PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Check the appliance the power cord the power plug and all accessories for transportation damages Keep the packaging materials as far as possible till the end ...

Page 3: ...ol 5 2 Electrical safety Always check that the power supply corresponds to the voltage on the rating plate Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges a...

Page 4: ...ents changing accessories or storing power tools Such preventive safety measures reduce the risk of starting the power tool accidentally Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained users Maintain power tools Check for misalignment or st...

Page 5: ...it Irom the machine Always disconnect the hammer drill Irom the electric supply before you change a chisel or drill bit Protect your eyes and other workers from flying particles and splinters Wear a helmet Set up partition walls Wear work gloves to protect fingers from bruising and grazing Vibrations can injure the hand arm system Keep exposure to vibrations as short as possible Always lead the ma...

Page 6: ...e handle attachment and place the straight part of the depth stop in the hole Adjust the depth stop and retighten the handle attachment 8 4 Dust collection device Fig 4 Before carrying out hammer drilling work vertically overhead pull dust collecting device over the drill bit 8 5 Hammer drill switch The hammer drill switch can switch the drill hammer and hammer drill functions To set the function ...

Page 7: ...h preferably after each use Keep the ventilation slots free from dust and dirt If the dirt does not come off use a soft cloth moistened with soapy water Never use solvents such as petrol alcohol ammonia water etc These solvents may damage the plastic parts 10 TECHNICAL DATA Rated Voltage 220 240 V Rated Frequency 50 Hz Rated Power 900 W Rotation speed 850 min 1 Protection class II Drill capacity c...

Page 8: ...odily injury resulting from inappropriate use of the tool Repairs may only be carried out by an authorised customer service centre for Powerplus tools You can always obtain more information at the number 00 32 3 292 92 90 Any transportation costs shall always be borne by the customer unless agreed otherwise in writing At the same time no claim can be made on the warranty if the damage of the devic...

Page 9: ...conformity with the essential requirements and other relevant provisions of the applicable European Directives based on the application of European harmonized standards Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2006 42 EC 2014 30 EU 2000 14 EC Annex V LwA 103dB 106dB Euro...