For the user
Värmebaronen Viking Bio 200
29
Disconnect the burner from the power
before working on it.
Changing the inner burner pipe
Detach the burner from the outer burner pipe. Unscrew
the locking screw approximately 10 mm, turn the inner
burner pipe anticlockwise and pull out the pipe.
Refit in reverse order.
Check the condition of the outer burner pipe as well.
Locking
screw
Changing the ignition element
1. Detach the burner from the outer burner pipe.
Unscrew the locking screw approximately 10 mm,
turn the inner burner pipe anticlockwise and pull out
the pipe.
2. Detach the ignition element cover by inserting the
ignition element tool into the arrow-shaped opening
and turning half a turn.
3. Press the hose on the ignition element tool over the
element until it touches bottom. Carefully withdraw
the ignition element. Recycle appropriately.
4. Press the new ignition element carefully into the
holder, using a finger, until it touches bottom.
Ensure that the slot is correctly located in the holder.
5. Place the ignition element cover with the arrow
upwards in its position using the ignition element
tool. Turn half a turn until the arrow points
downwards.
7. Refit the inner burner pipe and tighten the locking
screw.
The pellet stop must be in a horizontal position.
Ignition element tool
Ignition element
Ignition element
cover
Resetting the thermal relay
Switch off the power to the burner before
the thermal relay's enclosure is removed.
Unscrew the screws by the downpipe approximately
2 turns so that the cover plate can be pushed away
from the downpipe so that the thermal relay is
accessible.
Reset it by pressing in the button using a chisel.
Push back the cover plate and tighten the screws.
Restart the burner.
Screws
Cover plate
Reset button
Installation/removal of the pellet stop
The pellet stop is removed with the outer burner pipe
removed. Remove the pellet stop by angling it up
towards the centre of the pipe. Then it can be detached
from its position. Fit in the reverse order.
Pellet brake
Pellet stop