Installation
Värmebaronen Viking Bio 200
13
The burner must disconnected from the
power supply before work is carried out on
it or it is removed from the boiler.
1
2
3
4
5
6
F
N
N
F
1
2
/4
1
2
+
-
F
N
M
80°C
M
N
X2
L1 B4 S3 T2 T1
N
L1 B4 S3 T2 T1
Termosta
t
Alarm
10A
230 V~
GND
Ash removal motor
External temperature sensor
Flame guard
Thermostat
input
Fan
Ignition element
Auger motor
Thermal relay, downpipe
Alarm
N: neutral conductor, blue.
: earth conductor, PE, yellow/green.
L1: supply via overheating protection, black.
B4: boiler thermostat, brown.
S3: alarm signal, 230 V~, grey.
Display circuit board,
installed in the burner's
cover
Cable, connects display circuit
board to power circuit board.
Be careful when removing the cover so that
the cable between the circuit boards is not
damaged!
Power circuit
board with
power supply
unit