13
Part
Action
Frequency
Note
Safety guard
Check the safety of the safety guard:
Does the tool stop rotating when the
safety guard is tilted/removed?
Regularly
If the tool does not immediately
stop rotating on tilting/removal of
the safety guard, the machine must
not be used.
Call the servicer
Emergency stop
Test the emergency stop: Does the tool
stop rotating when the emergency stop
is activated?
Regularly
If the tool does not immediately
stop rotating on activation of the
emergency stop, the machine must
not be used.
Call the servicer
Mixer head
The mixer head should only be
lubricated on repair, see the section
“Lubrication and grease types” page 12
.
During repairs
The machine’s
other moving
parts
The moving parts that belong to the
bowl’s lifting mechanism all run in
maintenance-free plain bearings and
should not therefore be lubricated.
Never
Attachment drive
The rubber plug for covering the
opening of the attachment drive should
be on the machine and be intact.
Daily
The rubber plug must cover the
opening on the attachment drive
when the latter is not in use
.
Cleaning
Follow the instructions in the section
“Cleaning” page 12
Follow the instructions
in the section “Cleaning”
Systematic maintenance:
Reading the machines data:
Press the stop button for 5 sec. The machine’s data will then be displayed as alternating text in the display. There are
five readings corresponding to the five data sets described below:
•
Data set 1:
States firmware version, displayed as “F” followed by three figures, e.g.
= firmware version 3.
•
Data set 2
: States the machine’s running time, displayed as “t” followed by three figures, which indicate the number of
9.999-minute cycles, e.g.
= 2 x 9.999 min., or 19.998 min.
•
Data set 3
: Displays four figures, which indicate the number of minutes the current cycle has been running, e.g.
= 1.234 min.I.e., if
is displayed followed by
, the machine has been running for 19.998 min. + 1.234
min., or a total running time of 21.232 min.
•
Data set 4
: States the number of times the machine has been disconnected from the power supply (plug pulled out of the
machine/power outage/switched off) and restarted, displayed as “r” followed by three figures, which indicate the number
of restarts, e.g.
= 2 x 9,999 restarts, or 19,998 restarts.
•
Data set 5
: Displays four figures, which indicate the number of restarts which have happened in the current cycle, e.g.
= 1234 times. In other words, if
is displayed followed by
, the machine has restarted a total of 19,998
+ 1,234 times, or 21,232 times.
Reading the error log:
It is possible to display a log of the errors that have occurred:
• Hit emergency stop and press
next to
.
•
The display shows the latest error first.
• To scroll back through the errors, press
next to
; to scroll forward, press
next to
.
• The last eight errors can be displayed.
• Deactivate emergency stop to cancel the display.
Summary of Contents for KODIAK V20KT
Page 15: ...15 Mixer Spare Parts...
Page 19: ...19 16 10 11 5 15 7 8 9 2 17 9 6 13 12 1 LIFTING SYSTEM...
Page 23: ...23 ATTACHMENT DRIVE CR20 10 6Z CR30 50 6Z 2 5 7 7 8 9 13 11 16 1 6 10 4 3 4 12 14 15...
Page 32: ...Varimixer USA 2215 East River Road Moraine Ohio 45439 P 800 222 1138 varimixerusa com...