Figure 3-3. Blue/Amber Bulkhead Assembly Sensor Removal and Replacement
Step 4.
Prepare replacement sensor.
a. At replacement sensor assembly, using needle-nosed pliers,
bend unused sensor lead to 45 degree angle.
b. Trim sensor assembly wires to 15 inches.
CAUTION:
To avoid poor connections, do not reuse MTA connector
from removed sensor on replacement sensor.
c. Using MTA crimper, crimp wires into new 4-pin MTA
connector using the following pinouts:
Pin
Wire
4
Blue
3
Blue
2
N/C
1
N/C
d. Install strain relief cover on 4-pin connector. Using
permanent ink marker, mark strain relief either BLUE or
AMB as necessary.
CAUTION: Do not overtighten nuts when installing replacement sensor.
e. Install replacement sensor and re-install blue/amber
bulkhead by doing Steps 2 and 3 in reverse.