background image

8

VL1600 PROFILE

 

QUICK START GUIDE

443581625410 REV 00 10/21

SAFETY WARNINGS AND NOTICES

Read this user manual in full before attempting to install, operate or maintain the fi xture to which it relates. This user manual is intended to pro-
vide general guidance to such suitably qualifi ed personnel. Installation and operation of the fi xture are to be performed by qualifi ed personnel 
only.

When using electrical equipment, basic safety precautions should always be followed including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

SAVE THESE INSTRUCTIONS.

WARNING:

 Refer to National Electrical Code® and local codes for cable specifi cations. Failure to use proper cable can result in damage to 

equipment or danger to personnel.

COMPLIANCE NOTICE

FCC DECLARATION OF CONFORMITY 

This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with Vari-Lite Strand system, 
service, and safety guidelines, may cause harmful interference to radio communications.

As tested under this standard:

FCC 47CFR 15B clA*CEI

Issued:2009/10/01 Title 47 CFR Part 15 Subpart B Unintentional Radiators Class A

Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the 
interference at his/her own expense.

EU DECLARATION OF CONFORMITY

We, Vari-Lite LLC., 10911 Petal Street, Dallas, Texas 75238, declare under our responsibility for the products contained herein are in conformity 
with the essential requirements of the following European Directives and harmonized standards:

Low Voltage Director (LVD), 2006/95/EC

EN 60589-2-17:1984+A1:1987+A2:1990 used in conjunction with 60598-1:2008/A11:2009

•  For indoor, dry location use only. Do not use outdoors unless fi xture 

is suitably IP rated.

•  Use safety tether when mounting.
•  Equipment should be mounted in locations and at heights where 

it will not be readily subjected to tampering by unauthorized 
personnel.

•  Not for residential use. Do not use this equipment for other than 

intended use.

•  Note distance requirement(s) from combustible materials or 

illuminated objects. Do not mount near gas or electric heaters.

•  Install only in locations with adequate ventilation. Ensure sure that 

ventilation slots are not blocked.

•  Ensure that the voltage and frequency of the power supply match 

the power requirements of the fi xture.

• The 

fi xture must be earthed/grounded to the appropriate conductor.

•  Do not operate fi xture outside the specifi ed ambient temperature 

range.

•  Do not connect the fi xture to any dimmer pack.
•  The use of accessory equipment not recommended by the 

manufacturer may cause an unsafe condition and void warranty.

•  Refer service to qualifi ed personnel. This fi xture contains no user 

serviceable parts.

•  Prior to fi rst use, carefully inspect fi xture to ensure no damage has 

occurred during shipping.

•  Materials used in the manufacturing process can cause strong odors 

when the product is new. These odors dissipate over time.Prior to 

each use, carefully inspect power cables and replace any damaged 
cables.

•  Exterior surfaces of the luminaire will be hot during operation. Take 

appropriate precautions.

•  Continuous use of the fi xture may shorten the lifespan. Power down 

the fi xture when not in use.

•  Do not cycle power on and off  repeatedly. Disconnect mains power 

if the fi xture is not used for an extended period.

• Clean 

fi xtures regularly, particularly when working in a dusty 

environment.

•  Never touch power cables or wires while the fi xture is powered on.
•  Avoid entangling power wires with other cables.
•  In the event of a serious operating problem, immediately 

discontinue using the fi xture.

•  It is hazardous to operate luminaires without lens or shield. Shields, 

lenses, or ultraviolet screens shall be changed if they have become 
visibly damaged to such an extent that their eff ectiveness is 
impaired, for example, by cracks or deep scratches.

•  Original packing materials can be reused for transporting the 

fi xture.

•  Do not look directly at the LED light beam while the fi xture is on.
•  This is a Class A product. In a domestic environment this product 

may cause radio interference, in which case, the user may be 
required to take adequate measures.

•  The light source contained in this luminaire shall only be replaced by 

the manufacturer or service agent or similarly qualifi ed person.

©2022 Signify Holding. All rights reserved.

All trademarks are owned by Signify Holding or their respective owners. 
The information provided herein is subject to change, without notice. 
Signify does not give any representation or warranty as to the accuracy 
or completeness of the  information included herein and shall not be li-
able for any action in reliance thereon. The information presented in this  
document is not intended as any commercial off er and does not form 
part of any quotation or contract, unless otherwise agreed by Signify. 
Data subject to change.

CUSTOMER SERVICE

If you have any questions regarding this product, please con-
tact Customer Service by phone at +1 214-647-7880 or by email 
at [email protected].

8

Summary of Contents for VL1600 PROFILE

Page 1: ...phase service in countries with 240V power INSTALLATION AND SETUP DATA IN DATA THRU USB NETWORK AC POWER THRU AC POWER INPUT WIRE CONNECTION Green yellow AC ground Blue AC neutral Brown AC line Inter...

Page 2: ...is manual are designed to sit directly on its base in a oor installation application When used in this type of application be sure to leave enough space around the luminaire to allow proper uninterrup...

Page 3: ...l mounting hardware and brackets Step 1 Install truss hooks on two provided truss hook brackets as required as shown NOTE Various types of truss hooks can be used The Mega Claw truss hook as well as m...

Page 4: ...at least once around safety cable anchor point rod b Loop safety cable at least once around truss pipe and secure around pipe Step 4 Make sure tilt and pan locks are disengaged so luminaire moves fre...

Page 5: ...Previous Menu Item Arrow Keys Up Down Left Right Menu Navigation Data Selection ESC OK Displays all Data and Luminaire Settings MENU CONTROLS The menu system is controlled by an OK Enter ESC Escape a...

Page 6: ...Gobo Wheel 1 Rot Index High 20 Gobo Wheel 1 Rot Index Low 21 Gobo Wheel 1 Control 22 VLFX Wheel Gobo wheel 2 23 VLFX Rot Index High 24 VLFX Rot Index Low DMX CHANNEL PARAMETER 25 VLFX Wheel Control 2...

Page 7: ...3 Frame 4A 34 Frame 4B 35 Frame Rotate 36 Varible Frost 37 Strobe Shutter 38 Programmers Channel 39 Variable Fan Control 40 Luminaire Control Channel WARNING It is not recommended to power any Vari Li...

Page 8: ...hat the voltage and frequency of the power supply match the power requirements of the xture The xture must be earthed grounded to the appropriate conductor Do not operate xture outside the speci ed am...