Page 31
F3:
Adjusts the values on the ramping curve. The
LED display shows NN:VVV. NN represents the
point’s number whereas VVV represents point N’s
corresponding temperature value. When Growth
Day is OFF, VVV flashes and can be adjusted
with the + and - buttons. Press F3 to switch
points.
The following graph shows a typical ramping curve for
the main set point.
This five point curve may be entered as follows:
1 Make sure the Growth Day setting is OFF (see section
3.2.2).
2 Select the Main Set Point parameter with the arrow
buttons.
3 By now, the LCD should read "Main Set Point”. The
value on the LED display should be flashing. If not, it is
because the GrowthDay parameter is still ON.
Figure 10 Typical Ramping Curve
www.monitrol.com
Summary of Contents for IC-610
Page 1: ...IC 610 USER S MANUAL www monitrol com ...
Page 10: ...Page 10 IC 610 Intelligent Control CHAPTER 2 INSTALLATION www monitrol com ...
Page 11: ...Page 11 www monitrol com ...
Page 17: ...Page 17 Figure 4 IC 610 Main Board for board 1059 D www monitrol com ...
Page 25: ...Page 25 www monitrol com ...
Page 26: ...Page 26 IC 610 Intelligent Control CHAPTER 3 USER S GUIDE www monitrol com ...
Page 28: ...Page 28 IC 610 Intelligent Control CHAPTER 3 USER S GUIDE www monitrol com ...
Page 38: ...Page 38 IC 610 Intelligent Control APPENDIX www monitrol com ...
Page 42: ...Page 42 IC 610 Intelligent Control www monitrol com ...
Page 44: ...MAV IC 610 Ver 4 2 Rev 04 07 2001 www monitrol com ...