TECHNICAL INFORMATION
,
WARNING!
If you have to perform maintenance on the pump after a considerable time in operation, leave it to cool as
temperature of the outer surface may be in excess of 60 °C.
1. Drain off the oil from the pump.
NOTE
For a description of how to drain off the oil, see the Unscheduled Maintenance Card No. 102.
2. Unscrew the securing screws (71) and disconnect the flange (85) from the casing.
3. Take out the OR gasket (87) and the sight glass (86).
NOTE
When reassembling, replace the gaskets that you have stripped down.
CAUTION
When reassembly is complete, proceed to fill the pump with oil again following the instructions of Unsched-
uled Maintenance Card No. 102.