Control Channel Functions
Control channel functions allow special actions such as reset, lamp on/off and partial recalibration.
These must be executed with zero time transition or with timing disabled. Discrete values must be
used; not manual controls such as faders or encoders (see chart below for values).
Reset
- resets all luminaire mechanisms.
Lamp On or Lamp Off
- switches lamp on or off.
Partial Recalibration
- resets only the target mechanism (color, gobo, zoom, etc.) without affecting
others.
To use control channel functions:
Step
1. Select an action to be sent.
Step
2. Set control channel value for desired action (for example, 84 for reset). Hold value for 3
seconds.
Step
3. Set control channel value to zero. (This must occur without any scaling values. Action will
be voided if other values are detected between action value and zero.)
Note:
A numerical keypad is required for sending values. An encoder or fader does not allow for a
quick value change, which is required to effect the control functions.
Table 3-3: Control Channel Functions
Control
Channel
Function
Control Channel Value
% Value
DMX Value
For 3 Secs
or Greater
After
3 Secs
Luminaire Reset
32-33
81-87
0
Lamp Off
65-67
165-171
0
Lamp On
98-100
249-255
0
Partial Recalibration of:
- Color
40
100-104
0
- Gobos
45
112-116
0
- Edge/Zoom/Iris
50
126-130
0
- Dimmer/Strobe
55
138-142
0
Summary of Contents for VL3000 Series
Page 1: ......
Page 13: ...FOREWORD 02 9678 0001 A 20 Aug 03 xi...
Page 14: ...VARI LITE VL3000 SERIES LUMINAIRE USER S MANUAL xii 20 Aug 03 02 9678 0001 A...
Page 18: ...VARI LITE VL3000 SERIES LUMINAIRE USER S MANUAL xvi 20 Aug 03 02 9678 0001 A Notes...
Page 70: ...VARI LITE VL3000 SERIES LUMINAIRE USER S MANUAL 52 20 Aug 03 02 9678 0001 A Notes...
Page 80: ...VARI LITE VL3000 SERIES LUMINAIRE USER S MANUAL 62 20 Aug 03 02 9678 0001 A Notes...
Page 86: ......