02.9676.0022 0
Troubleshooting Guide
If a problem is suspected, try recalibrating the luminaire to prompt an error message. Refer to
the Troubleshooting Guide table (below) for more information. This table provides possible
causes and remedies for each message.
Table 2-2: Troubleshooting Guide
Message
Symptom
Description
Possible Cause and Remedy
n/a
No response to DMX
data
DMX Failure
MCB connector disconnected...
- check MCB DATA IN connection.
n/a
Lamp douses frequently
Lamp Douse
Fan failure...
- check fans for proper connection and
operation.
n/a
Lamp will not strike
Lamp Strike Failure
Lamp cutout switch disengaged...
- check lamp cutout switches at lamp box
and fan ducts.
Bad lamp...
- replace lamp.
Low input voltage...
- check input power (must be 200 to 264 VAC)
Lamp
Power
Douse
Lamp does not strike
upon start-up
Lamp Off option is config-
ured
Reconfigure lamp startup option in Lamp config
menu
n/a
Luminaire behaves
oddly
Profile Not Matched
Profile not set correctly...
- check Setup menu for correct type (spot or
wash).
- check start DMX address
No Sens
No control, continuous
recalibration, and/or
mechanism at wrong
position
Mechanism failed to find
sensor (reported for
Cyan, Yellow, Magenta,
ColWheel, Dimmer and
Edge)
Motor power not connected...
- connect motor power.
Sensor not connected...
- connect sensor.
Movement restricted or impeded...
- remove obstruction, check cable routing,
and/or check voltage at MCB test point.
n/a
Luminaire does not
power-up
No power
Switch not turned on...
- verify switch is turned on.
Not plugged in...
- ensure A/C cable is connected to power
source.
Pan/
Encoder/
Fail
Luminaire will not pan
Pan Encoder Failure
MCB pan/tilt connector disconnected...
- connect MCB pan/tilt connector (J8).
Pan motor disconnected
- connect pan motor power.
Encoder faulty...
- replace pan end-of-travel/encoder sensor
assembly.
Summary of Contents for VL2500 Spot Luminaire
Page 1: ......
Page 18: ...VARI LITE VL2500 WASH LUMINAIRE SERVICE MANUAL xviii 09 December 2004 02 9676 0022 0 Notes...
Page 124: ...VARI LITE VL2500 WASH LUMINAIRE SERVICE MANUAL 106 09 December 2004 02 9676 0022 0 Notes...
Page 148: ...VARI LITE VL2500 WASH LUMINAIRE SERVICE MANUAL 130 09 December 2004 02 9676 0022 0 Notes...
Page 167: ......