M
ENU
S
YSTEM
: O
PERATION
4
0 2 . 9 6 7 1 . 0 0 0 1 C
17 - Se pt - 01
55
Error Messages
If a problem occurs during luminaire calibration, at the end of the calibration sequence
the Menu Display will cycle through any applicable error message(s), one at a time
until the end of the list is reached. To review the error messages again, it will be
necessary to access them using the Status function. (Refer to
for a list of possible causes and remedies associated with the error messages.)
Access Error Messages:
1. Press [Menu].
2. Press [Up] / [Down] arrows until
Fixt
(Fixture) appears. Press [Enter].
3. Press [Up]/ [Down] arrows to access
STAT
. Press [Enter]. (Display will now
scroll through any error messages or display
OK
if no errors.)
Table 4-1: Error Messages
Display
Message...
OK
No Errors Found
B1M1 / MAG / NoSn
Aux Board 1, Motor 1 / Magenta / Sensor Not Found
B1M1 / MAG / SAct
Aux Board 1, Motor 1 / Magenta / Sensor Always Active
B1M2 / Dimm / NoSn
Aux Board 1, Motor 2 / Dimmer / Sensor Not Found
B1M2 / Dimm / SAct
Aux Board 1, Motor 2 / Dimmer / Sensor Always Active
B1M3 / CWhl / NoSn
Aux Board 1, Motor 3 / Color Wheel / Sensor Not Found
B1M3 / CWhl / SAct
Aux Board 1, Motor 3 / Color Wheel / Sensor Always Active
B2M1 / Blue / NoSn
Aux Board 2, Motor 1 / Blue / Sensor Not Found
B2M1 / Blue / SAct
Aux Board 2, Motor 1 / Blue / Sensor Always Active
B2M2 / Ambr / NoSn
Aux Board 2, Motor 2 / Amber / Sensor Not Found
B2M2 / Ambr / SAct
Aux Board 2, Motor 2 / Amber / Sensor Always Active
BRD1 / NO / COMM
Aux Board 1 Communication Failure
BRD2 / NO / COMM
Aux Board 2 Communication Failure
HEAD/ OVER/ TEMP
Head Over Temperature
LAMP / STRK / FAIL
Lamp Strike Failure
PAN / ENCR / FAIL
Pan Encoder Failure
PAN / NO / SENS
Pan Sensor Not Found
PAN / SENS / ACTV
Pan Sensor Always Active
SRCH/FOR/BRD1
Attempting to communicate with Board 1
SRCH/FOR/BRD2
Attempting to communicate with Board 2
TILT / ENCR / FAIL
Tilt Encoder Failure