Menu Operation

LCD Display and Menu System

The VL1100 LED Luminaire’s LCD Display and Menu System provides local control for accessing the following fixture’s settings:

Address – to set the DMX address

Setup – to change any modes

Configure – various parameter settings, set luminaire ID

Fixture – fixture status, recalibrate, reboot, software version, view fixtures hours, etc.

DMX – change the map, set address, invert pan/tilt

Manual – manual control of parameters

Test – test functions of parameters

The menu system is controlled at the Menu Display available at the enclosure input panel. If there are multiple luminaires in a system, any 

settings or changes would need to be made at each LCD Menu as desired.

Menu Controls

The menu system is controlled by an OK (Enter), ESC (Escape), and four Arrow (



) buttons. These buttons function are shown in 

Figure 6

.

Figure 6:   Menu Control

LCD Display and Menu System Operation

The LCD Display Menu system consists of several categories. Use the menu buttons to access and make changes to menu items. When the 

desired menu item is reached, press [Menu] button to display the menu options and to navigate and configure options as needed.

The menu system is controlled by four buttons. These buttons function as follows:

[Menu] button – Displays the menu, or if at first level, the current address. Can also enable menu to exit a menu level.

[Enter] button – Selects the current menu option or stores current data value

[

] Down arrow – Scrolls menu options upward or increases current data value.

[

] Up arrow – Scrolls menu options downward or decreases current data value.

To navigate and access menu settings/selections:

Step

1. Make sure unit is powered and turned on.

Step

2. Press [Menu] to display1st level functions. 

Step

3. Scroll through the 1st level functions by pressing [



] arrows. 

Step

4. Once the desired function appears in the display, press OK [Enter] to access 2nd level functions. 

Step

5. Use the [



] arrows to scroll through 2nd level functions. 

Step

6. Press [Enter] to access 3rd level functions. When the highest level for the function is reached, [



] arrows can be pressed to 

select a value or select a toggle activation such as ON/OFF. 

Step

7. Press OK [Enter] to store the value or select an action.

Menu
Display

Up / Increase

Down / Decrease

LCD Display

Press to select current menu

option or current data value.

Press to

show menu,

or if at first

level, the

current

address.

Address

Summary of Contents for VL1100

Page 1: ...VARll llllE VL1100 LED Luminaire QuickStart Guide...

Page 2: ...te for Theatre Technology USITT Recommended Practice for DMX512 A Guide for Users and Installers 2nd edition ISBN 9780955703522 USITT Contact Information USITT 315 South Crouse Avenue Suite 200 Syracu...

Page 3: ...manual and any accompanying documentation before installing and operating the products described herein Heed all cautions and warnings during installation and use of this product Safety symbols used t...

Page 4: ...OUR SE PROT GER CONTRE LES D CHARGES LECTRIQUES 1 Les luminaires VARI LITE sont con us pour une utilisation au sec uniquement Une exposition la pluie et l humidit risque d endommager le luminaire 2 D...

Page 5: ...AC Input Cable Neutrik powerCON TRUE1 with Twist Lock Male 250V 1 Meter PCT1GP AC Input Cable Neutrik powerCON TRUE1 with Stage Pin Male 1 Meter PCT1SB AC Input Cable Neutrik powerCON TRUE1 with Ediso...

Page 6: ...tor Depending on the application the luminaire s AC input cable may require a different connector If required install a new connector meeting your requirements using the following wire color code refe...

Page 7: ...pecific voltages Total Luminaire Current is calculated with the lamp on and all motors sequencing WARNING It is the responsibility of the user to adequately protect supply source with a correct size a...

Page 8: ...Link Step 4 Connect AC Input Cable connector to power input source Step 5 Dress AC input and data cables and secure them so that they will not interfere with luminaire head and yoke movement VL1100 L...

Page 9: ...low can be ordered separately from Vari Lite refer to Replacement Items Accessories on page 4 To install truss hooks if required Step 1 At pan tube base attach two truss hooks as shown in Figure 4 Ste...

Page 10: ...START GUIDE 9 24 April 2017 02 1602 0001 Figure 5 Example VL1100 LED Luminaire Truss Hanging Installation 34 5 87 6cm 17 5 44 5cm 26 5 67 3cm 26 66cm Safety Cable Recommended for all hanging installat...

Page 11: ...em is reached press Menu button to display the menu options and to navigate and configure options as needed The menu system is controlled by four buttons These buttons function as follows Menu button...

Page 12: ...removed Refer to your console operating instructions for specific information regarding its addressing requirements To program a DMX starting address Step 1 Press Menu Step 2 Press arrows until Addres...

Page 13: ...LED S LED HP S DMX Channel Summary Listing DMX Channel Description DMX Channel Description 1 Dimmer 11 Magenta 2 3 Pan 12 Rotating Gobo 4 5 Tilt 13 14 Gobo Index 6 Edge 15 Beam 7 Zoom 16 Focus Time 8...

Page 14: ......

Reviews: