SAFETY WARNINGS AND NOTICES

Read this document and the related user manual in full before attempting to install, operate or maintain the fi xture to which it relates. This user manual is intended 

to provide general guidance to such suitably qualifi ed personnel. Installation and operation of the fi xture are to be performed by qualifi ed personnel only.

When using electrical equipment, basic safety precautions should always be followed including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

•  For indoor, dry location use only. Do not use outdoors unless fi xture is 

suitably IP rated.

•  Use safety tether when mounting.

•  Equipment should be mounted in locations and at heights where it will 

not be readily subjected to tampering by unauthorized personnel.

•  Not for residential use. Do not use this equipment for other than intended 

use.

•  Note distance requirement(s) from combustible materials or illuminated 

objects. Do not mount near gas or electric heaters.

•  Install only in locations with adequate ventilation. Ensure sure that 

ventilation slots are not blocked.

•  Ensure that the voltage and frequency of the power supply match the 

power requirements of the fi xture.

•  The fi xture must be earthed/grounded to the appropriate conductor.

•  Do not operate fi xture outside the specifi ed ambient temperature range.

•  Do not connect the fi xture to any dimmer pack.

•  The use of accessory equipment not recommended by the manufacturer 

may cause an unsafe condition and void warranty.

•  Refer service to qualifi ed personnel. This fi xture contains no user 

serviceable parts.

•  Prior to fi rst use, carefully inspect fi xture to ensure no damage has 

occurred during shipping.

•  Materials used in the manufacturing process can cause strong odors when 

the product is new. These odors dissipate over time.

•  Prior to each use, carefully inspect power cables and replace any 

damaged cables.

•  Exterior surfaces of the luminaire will be hot during operation. Take 

appropriate precautions.

•  Continuous use of the fi xture may shorten the lifespan. Power down the 

fi xture when not in use.

•  Do not cycle power on and off  repeatedly. Disconnect mains power if the 

fi xture is not used for an extended period.

•  Clean fi xtures regularly, particularly when working in a dusty environment.

•  Never touch power cables or wires while the fi xture is powered on.

•  Avoid entangling power wires with other cables.

•  In the event of a serious operating problem, immediately discontinue 

using the fi xture.

•  It is hazardous to operate luminaires without lens or shield. Shields, 

lenses, or ultraviolet screens shall be changed if they have become 

visibly damaged to such an extent that their eff ectiveness is impaired, for 

example, by cracks or deep scratches.

•  Original packing materials can be reused for transporting the fi xture.

•  Do not look directly at the LED light beam while the fi xture is on.

•  This is a Class A product. In a domestic environment this product may 

cause radio interference, in which case, the user may be required to take 

adequate measures.

•  The light source contained in this luminaire shall only be replaced by the 

manufacturer or service agent or similarly qualifi ed person.

SAVE THESE INSTRUCTIONS.

WARNING: Refer to National Electrical Code® and local codes for cable specifi cations. Failure to use proper cable can result in damage to equipment or danger to 

personnel.

©2021 Signify Holding. All rights reserved.

All trademarks are owned by Signify Holding or their respective owners. The 

information provided herein is subject to change, without notice. Signify does 

not give any representation or warranty as to the accuracy or completeness of 

the  information included herein and shall not be liable for any action in reliance 

thereon. The information presented in this  document is not intended as any 

commercial off er and does not form part of any quotation or contract, unless 

CUSTOMER SERVICE

If you have any questions regarding this product, 

please contact Customer Service by phone at 

+1 214-647-7880 or by email at 

entertainment.

[email protected]

.

8

IEC/TR 62778 NOTICE ON RETINAL BLUE LIGHT HAZARD

For reference only. refer to product label for specifi c 

warnings for this product. 
risk Group 1

None

risk Group 2

cautiON! do not stare into beam.

risk Group 3

WarNiNG! do not look into the beam. 

No direct eye exposure to the beam is 

permitted.

WARNING: 

It is not recommended to power any Vari-Lite fixture from a dimmer - even in 'NONDIM' mode. Dimmer 

and non-dim modules are not suitable sources of power because their output modifies the AC wave form. This may 

work for a short time, but will eventually result in power problems, operating errors, and/or fixture failure and may 

void the warranty.

WARNING: 

It is the responsibility of the user to adequately protect supply source with a correct size and type circuit 

breaker and not overload circuits.

WARNING: 

This unit has a battery. Replace only with the correct type of battery. Failure to use the correct battery 

could cause serious damage to the fixture. Dispose of used batteries appropriately.

Summary of Contents for VL 2600

Page 1: ...ect to three phase service in countries with 240V power INSTALLATION AND SETUP AC power input WIRE CONNECTION Green yellow AC ground Blue AC neutral Brown AC line International Harmonized Standard For...

Page 2: ...g luminaire Two mounting truss hooks or other mounting hardware are required Many compatible truss hooks are available from different manufacturers for your particular needs A minimum of two hooks per...

Page 3: ...hook hardware that locks hook in place e g wing bolt is properly tightened and that luminaire is fully supported Step 3 Attach safety cable as required as follows a Loop safety cable at least once ar...

Page 4: ...splays all Data and Luminaire Settings MENU CONTROLS The menu system is controlled by an OK Enter ESC Escape and four Arrow buttons QUICK REFERENCE DMX MAPS The short form DMX maps are available on th...

Page 5: ...or Wheel Control 31 Frame 4B 46 Optical Style 17 Gobo Wheel 1 32 Frame Rotate 47 Luminaire Control 18 19 Gobo 1 Rot Index 33 Triangular Prism 20 Gobo Wheel 1 Control 34 35 Prism Index Rot Table 3 16 B...

Page 6: ...o Wheel 3 Control 38 Beam Timing 14 CTO 27 Iris 39 Gobo Timing 15 Color Wheel 28 Triangular Prism 40 Fan Control 16 Color Wheel Control 29 30 Prism Index Rot 41 Luminaire Control Table 5 16 BIT VL2600...

Page 7: ...ow 20 Frame 3B 30 Color Timing 11 Magenta 21 Frame 4A 31 Fan Control 12 CTO 22 Frame 4B 32 Luminaire Control 13 Color Wheel 23 Frame Rotate 14 Color Wheel Control 24 Frost Table 7 16 BIT VL2600 WASH D...

Page 8: ...of a serious operating problem immediately discontinue using the fixture It is hazardous to operate luminaires without lens or shield Shields lenses or ultraviolet screens shall be changed if they ha...