19
USER MANUAL
912400575012UM
WWW. ST R A N D L I G H T I N G .CO M
TABLE 6.
DMX MAP - ALL
CHANNEL 16-BIT 1 CELL
16-BIT 7 CELL
8-BIT 1 CELL
8-BIT 7 CELL
65
Strobe Speed
66
Strobe Control
67
Focus Timing
68
Optics Timing
69
Color Timing
70
Control Channel
DMX512 CONNECTION
•
At last unit, the DMX cable has to be terminated with a terminator. Solder a 120
1/4W resistor between
pin 2(DMX-) and pin 3(DMX+) into a 5-pin XLR-plug and plug it in the DMX-output of the last unit.
•
Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the input of the
next unit. The cable can not branched or split to a `Y` cable. DMX 512 is a very high-speed signal. Inad-
equate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut
down the system.
•
The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the
units’ power is disconnected.
•
Each lighting unit needs to have an address set to receive the data sent by the controller. The address
number is between 0-511 (usually 0 & 1 are equal to 1).
•
The end of the DMX 512 system should be terminated to reduce signal errors.
MAINTENANCE
TROUBLESHOOTING
Following are a few common problems that may occur during operation.
The unit does not work - light and fan do not turn on.
•
Check the connection of power and main fuse.
•
Measure the mains voltage on the main connector.
Not responding to DMX controller
•
DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
•
If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
•
If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the
previous one.
•
Try to use another DMX controller.
•
Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or inter-
ference to DMX interface circuit.
CLEANING
The cleaning of internal must be carried out periodically to optimize light output. Cleaning frequency depends
on the environment in which the fi xture operates: damp, smoky or particularly dirty surrounding can cause
greater accumulation of dirt on the fi xture’s optics.
•
Clean with soft cloth using normal glass cleaning fl uid.
•
Always dry the parts carefully.
•
Clean the external optics at least every 30 days.
TECHNICAL SPECFICATIONS
Refer to the product data sheet available for download on
www.vari-lite.com
.