ATEX Exemption
The 6700 Liquid Level Indicator (LLI) is considered a simple apparatus. It moves very slowly, and
has a low capacity to store energy. It is incapable of forming hot surfaces or other ignition
sources, even in cases of rare malfunction. Simple apparatus are not to be classified as ATEX
equipment or to be marked according to ATEX Directive 2014/34/EU.
For use in gas groups IIA, IIB, and IIC.
Installation Location
Wetted Parts
(float, cable, bottom anchor,
top anchors, sheave elbows)
Non-Wetted Parts
(gaugeboard, level indicator)
Hazardous locations – Zone 0
Yes
No
Hazardous locations – Zone 1
Yes
Yes
Hazardous locations – Zone 2
Yes
Yes
Normal (nonhazardous) locations
Yes
Yes